Page B-10
GTX 23 Installation Manual
Revision A
190-00906-01
B.6 Daisy Chain between Methods A and B
In rare situations where more braids need to be terminated for a connector than three per ring terminal and
a mixture of Methods A and B have been used, it is allowable to daisy chain a maximum of two shields
together from a Method A termination to a Method B (Figure B-7). All other restrictions and instructions
for the shield termination technique set forth for Method A and B are still applicable.
The maximum length of the combined braids should be approximately 4 inches.
Figure B-7 Daisy Chain between Methods A and B
B.7 Splicing Signal Wires
Figure B-8 illustrates that a splice must be made within a 3 inch window from
outside the edge of clamp to the end of the 3 inch max mark.
Keep the splice out of the backshell for pin extraction, and outside of the strain
relief to avoid preloading.
Figure B-8 shows a two wire splice, but a maximum of three wires can be spliced. If a third wire is spliced,
it is located out front of splice along with signal wire going to pin.
Splice part numbers:
•Raychem D-436-36/37/38
•MIL Spec MIL-S-81824/1
This technique may be used with shield termination methods: A.1, A.2, B.1, and B.2.
NOTE
NOTES
WARNING
Содержание GTX 23 ES
Страница 1: ...190 00906 01 August 2011 Revision A GTX 23 Transponder Installation Manual...
Страница 8: ...Page vi GTX 23 Installation Manual Revision A 190 00906 01 This page intentionally left blank...
Страница 22: ...Page 2 6 GTX 23 Installation Manual Revision A 190 00906 01 This page intentionally left blank...
Страница 32: ...Page 4 6 GTX 23 Installation Manual Revision A 190 00906 01 This page intentionally left blank...
Страница 45: ...GTX 23 Installation Manual Page B 11 190 00906 01 Revision A Figure B 8 D Sub Spliced Signal Wire illustration...
Страница 46: ...Page B 12 GTX 23 Installation Manual Revision A 190 00906 01 This page intentionally left blank...