GMA 347 Installation Manual
Page 4-9
190-00325-01
Revision A
4.3.6 External Configuration Module
The configuration module contains an I2C temp sensor and EEPROM. The configuration module is
located in the connector backshell. The configuration module stores a backup of the unit configuration.
Table 4-8. External Configuration Module Pin Assignments, J3472
Pin
Pin Name
Description
I/O
1
Configuration Module Ground
Ground
--
21
Configuration Module Power
+3.3 VDC
In
40
Configuration Module Data
Bi-directional data line
In/Out
60
Configuration Module Clock
Signal used to clock data input\output
Out
4.3.7
Speaker
The speaker output is capable of driving up to 10 Watts into a 4
ȍ
or 8
ȍ
speaker.
Table 4-9. Speaker Pin Assignments, J3472
Pin
Pin Name
Description
I/O
41
SPEAKER AUDIO OUT LO
Ground reference for speaker audio
--
42
SPEAKER AUDIO OUT HI
Speaker audio output
Out
4.3.8
PA MUTE
PA MUTE is an output that when pulled low is active. It is used to trigger the mute function on
an external PA system.
Table 4-10. PA MUTE Pin Assignments, J3472
Pin
Pin Name
Description
I/O
64
PA MUTE* OUT
Output capable of sinking 500 mA
Out
* Denotes Active Low (Ground to activate).
Содержание GMA 347
Страница 4: ...Page ii GMA 347 Installation Manual Revision A 190 00325 01 This page intentionally left blank ...
Страница 10: ...Page viii GMA 347 Installation Manual Revision A 190 00325 01 This page intentionally left blank ...
Страница 24: ...Page 2 8 GMA 347 Installation Manual Revision A 190 00325 01 This page intentionally left blank ...
Страница 52: ...Page 4 14 GMA 347 Installation Manual Revision A 190 00325 01 This page intentionally left blank ...