Part # 4517124 Rev. 7 (08/17/11)
Page 33
ERROR LOGIC & TROUBLESHOOTING
continued
Motor Error2
Occurs when the platen is in motion
and fails to reach the upper or lower
limit position within 30 seconds,
(150 encoder counts)
Recycle Main
Power Switch
Audio Alarm
L1: MOTOR
L2: ERROR2
Lower Switch Error
Occurs at cycle start when the
lower limit switch fails to signal the
platen’s arrival at the lower limit
position within 200 seconds.
Recycle Main
Power Switch
Audio Alarm
L1: LOWER SWITCH
L2: FAIL
Upper Switch Error
Appears in code,
but is never set.
Recycle Main
Power Switch
Audio Alarm
L1: UPPER SWITCH
L2: FAIL