Service-Manual, new version
author: Chr. Fuchs 17.06.99 / INDUCS Ltd. 18.09.03
page 5 of 28
2
Technical Information
Base-Line
Type 3500
SH/BA, SH/IN
208 V / 1 ph
230 V / 1 ph
240 V / 1 ph
Wattage kW
3.5
3.5
3.5
Current A
17
16
15
Power factor
Cos
> 0.95
> 0.95
> 0.95
> 0.95
> 0.95
> 0.95
Discharge rate mA
4
4
4
∅
coil mm
195
210
210
Type 5000
SH/BA, SH/IN
208V/ 3 ph
400 V / 3 ph
440 V / 3 ph
Wattage kW
5.0
5.0
5.0
Current A
14
8
7
Power factor
Cos
> 0.95
> 0.95
> 0.90
> 0.95
> 0.90
> 0.95
Discharge rate mA
4
4
4
∅
coil mm
210
210
220
Wok-Line
Type 3500
SH/WO, SH/WO/IN
208 V / 1 ph
230 V / 1 ph
240 V / 1 ph
Wattage kW
3.5
3.5
3.5
Current A
17
16
15
Power factor
Cos
> 0.95
> 0.95
> 0.95
> 0.95
> 0.95
> 0.95
Discharge rate mA
4
4
4
∅
Ceramic bowl mm
260
260
260
∅
coil mm
240
240
240
Type 5000
SH/WO, SH/WO/IN
208 V / 3 ph
400 V / 3 ph
440 V / 3 ph
Wattage kW
5.0
5.0
5.0
Current A
14
8
7
Power factor
Cos
> 0.95
> 0.95
> 0.90
> 0.95
> 0.90
> 0.95
Discharge rate mA
4
4
4
∅
Ceramic bowl mm
260
260
260
∅
coil mm
240
240
270
Max. tolerance of power supply
Nominal v6 / -10%
Frequency
50/60 Hz
Protection class
IP X0
Min. diameter of pans
Ca. 12 cm
Max. ambient temperature: stockage
-20 to 70
ºC/
0 to + 160º F
Max. ambient temperature: function
-5 to 40
º
C/ -40 to 110
º
F
Max. relative humidity of air: stockage
10 to 90%
Max. relative humidity of air: function
30 to 90%
Содержание SH/BA 3500
Страница 15: ...Service Manual new version author Chr Fuchs 17 06 99 INDUCS Ltd 18 09 03 page 15 of 28...
Страница 16: ...Service Manual new version author Chr Fuchs 17 06 99 INDUCS Ltd 18 09 03 page 16 of 28...
Страница 17: ...Service Manual new version author Chr Fuchs 17 06 99 INDUCS Ltd 18 09 03 page 17 of 28...