![Garland P10GSFPBPFE Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/garland/p10gsfpbpfe/p10gsfpbpfe_user-manual_3658177030.webp)
User Guide
XtraTAP™ Portable Packet Broker | P10GSFPBPFE | 4.22.1
Force Bypass If selected, the tap will switch the traffic between the network ports with no
regard for the inline appliance port(s), link or heartbeats. Typically used during
maintenance activities.
Figure 4 Bypass Mode (Force Bypass)
Force Inline
If selected, the tap bypass option is disabled. If an issue occurs with the inline
appliance port(s), loss of link or heartbeats, the traffic will go down.
Figure 5 Bypass Mode (Force Inline)
4. Select the Fail Mode.
Closed
If power is lost to the unit. The traffic will drop between the network ports.
5. LFP
If enabled and link is lost on one of the network ports. The TX will be disabled on
the other network port. The RX for both network ports remain on.
Figure 6 Bypass Mode (LFP)
6. Reverse Bypass
If enabled and the inline appliance port(s) fail, loss of link or heartbeats. The TX
will be disabled on both of the network ports. The RX for both network ports
remain on.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.
30