User Guide
XtraTAP | P10GxxFE-X | 4.22.1
UTC
1. Select Edit Settings.
2. Select the desired UTC using the pull down panel.
3. Select Save.
4. Select Cancel to return to the Date & Time Settings panel.
Manually Set Date & Time
1. Select Edit Settings.
2. Enter the Hours or use the up/down arrows to select.
3. Enter the Minutes or use the up/down arrows to select.
4. Enter the Date, MM/DD/YYYY or use the calendar to select.
5. Select Save.
6. Select Cancel to return to the Date & Time Settings panel.
NTP No Authentication (Symmetric)
The system supports an IPv4 or IPv6 address for NTP timing. If IPv4 is desired, then an IPv4
management interface must be assigned. If IPv6 is desired, then an IPv6 management interface
must be assigned. The system allows for an IPv4 and IPv6 management interface to be assigned
simultaneously.
1. Select Edit Settings.
2. Select NTP timing.
3. Enter the IPv4 or IPv6 Address.
4. Verify Authenticate, None.
5. Select Save.
The NTP Status will display “syncing”. Eventually the NTP Status will display “Synced”.
This can take several minutes.
6. Select Cancel to return to the Date & Time Settings panel.
NTP Authentication (Symmetric)
The system supports an IPv4 or IPv6 address for NTP timing. If IPv4 is desired, then an IPv4
management interface must be assigned. If IPv6 is desired, then an IPv6 management interface
must be assigned. The system allows for an IPv4 and IPv6 management interface to be assigned
simultaneously.
1. Select Edit Settings.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
19