12
6. Mounting Instructions
7. Operation And Test
The smoke alarm is operating once AC power is applied, the new
battery is installed and testing is complete. When the smoke alarm
senses smoke, the horn will sound a loud (85 db) pulsating alarm
( 3 beeps repeat ).
Red and Green LED indicators:
This smoke alarm features red and green LED indicators that can be
seen through the Push-to-Test button or the LED lens above the test
button.
The LEDs indicate the following:
GREEN
ON
– AC power is present.
OFF
– AC power is
not
present.
RED
Red LED Blinks once every 5 minutes and 20 seconds
– Mains power is present indicating normal operation.
Red LED Blinks once a second
– smoke alarm senses smoke and simultaneously sounds an
audible alarm
Red LED Blinks once every 10 seconds
– smoke alarm is in hush mode.
Red LED is 3 rapid flashes at 40 second intervals
– indicates which alarm previously detected an alarm condition.
Red LED OFF
–
DC power is not present.
OFF and unit is sounding alarm
–
Another interconnected smoke alarm has sensed smoke and
is signalling this alarm.
5. Now mount the smoke alarm onto the trim ring. Rotate the
ionisation smoke alarm until the ionisation smoke alarm snaps
firmly into place.
Note: Please ensure that battery is installed prior to mounting
of smoke alarm.