128-6453
1 of 8
Model APS-25CH
Installation Manual
Note : When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver’s door pin switch
in order to begin the passive arming sequence.
RF Programmable Features :
Feature Selection
1 Chirp
2 Chirps
3 Chirps
4 Chirps
Default
1st Door L/UL
1 Sec.
3.5 Sec.
1 Sec L, Dbl. U/L
1 Sec.
2nd Accy Lock
Auto Lock On
Auto Lock Off
Auto Lock Off
3rd Accy. UL
Auto UL On
Auto UL Off
Auto UL Off
4th Passive Locks
Passive
Active
Active
5th Passive/Active Arm
Passive Arm
Active Arm
Active Arm
6th Voltage Sense
Voltage Sense Hardwire
Hardwire
To program these selectable features;
Action
System Response
Turn ignition on
No response
Press and release the valet switch 3 times
1 Chirp - LED 1 flash
Within 3 seconds, turn ignition Off
Short chirp, then long chirp
First
Then On
1 chirp = 1 second door locks
Press transmitter Lock button to change
2 chirps = 3.5 second door locks
Press transmitter Lock button to change
3 chirps = 1 sec. lock, dbl 1 sec. unlock
o r
Second
Press and release the valet switch
2 chirps = auto locks off
Press transmitter Lock button to change
1 chirp = auto locks on
o r
Third
Press and release the valet switch
2 chirps = auto unlock off
Press transmitter Lock button to change
1 chirp = auto unlock on.
o r
Fourth
Press and release the valet switch
2 chirps = active locks
Press transmitter Lock button to change
1 chirp = passive locks
o r
Fifth
Press and release the valet switch
2 chirps = active arming
Press transmitter Lock button to change
1 chirp = passive arming
o r
Sixth
Press and release the valet switch
2 chirps = hardwire
Press transmitter Lock button to change
1 chirp = voltage sense
o r
Turn ignition key off
Exit program mode
Note: Once you enter the feature programming mode, do not allow more than 30 seconds to pass between steps, or the
programming will be terminated.