7. Operation and Test

TESTING THE SMOKE ALARM

  Warning: test each smoke alarm to be sure that each is 

installed correctly and is operating properly.

Stand at arm’s length from the smoke alarm when testing. The alarm 
sounder is loud to alert you to an emergency and can be harmful to 
hearing.
Test the smoke alarm weekly and upon returning from holiday, or 
when the house has been unoccupied for several days. 

Test all smoke alarms weekly by doing the following:

1. Check the Hush/Test button. If the green LED above the test button 

is ON, the smoke alarm is receiving AC power.

2. Firmly depress and hold the Hush/Test button for at least five (5) 

seconds. The smoke alarm will sound 3 long beeps, pause, 3 longs 

beeps, repeating for up to 10 seconds after the Hush/Test button 

is released. 

NOTE:

 If smoke alarms are interconnected, all smoke 

alarms should sound an alarm within three (3) seconds after any 

test button is pushed and the tested smoke alarm sounds.

3. If the smoke alarm does not sound, turn off the power to the smoke 

alarm circuit at the main distribution board and check the wiring. 

Retest the smoke alarm. If the smoke alarm does not sound, please 

refer to Section 9: Troubleshooting. If this doesn’t work please 

contact your electrician.

 Warning: If alarm horn sounds, and smoke alarm is 

not being tested, the smoke alarm is sensing smoke. THE 
SOUND OF THE ALARM HORN REQUIRES YOUR IMMEDIATE 
ATTENTION AND ACTION.

Содержание Ongard OG10

Страница 1: ...ly read this user guide which should be saved for future reference and passed on to any subsequent owner Ionisation Smoke Alarm with Hush User Guide 240V AC 50Hz 80mA max 9V back up single and or mult...

Страница 2: ...Safety Habits 18 14 What To Do When the Alarm Sounds 19 15 Warranty Contact Details 20 Thank you for purchasing this smoke alarm It is an important part of your family s home safety plan You can trus...

Страница 3: ...or model of smoke CO or heat alarm Hush quiets unwanted alarms for up to 10 minutes Alarm memory identifies which alarm has activated Optional use tamper resistant feature serves as a safeguard again...

Страница 4: ...any combination of 17 other alarm models Compatible Models include OG10 OG20 OG20LL OG30 Operating Temperature 0 C to 40 C Operating Humidity Up to 93 Humidity Non Condensing Lound Alarm 85 decibels a...

Страница 5: ...r humidifiers If a hallway or room is more than 9 1m long put alarms at both ends For maximum household protection see Figure 1C Things to Consider For Ceiling Mounting Smoke from a fire will rise to...

Страница 6: ...MENT KITCHEN HALL GARAGE MASTER BEDROOM FIRE EXTINGUISHERS SMOKE ALARMS FIRE BLANKET or Heat Alarm DINING ROOM LIVING ROOM Smoke Alarms for Minimum Protection IonisationType Smoke Alarm with Alarm Sil...

Страница 7: ...CEILING PEAK CEILING 300mm MINIMUM 600mm MINIMUM MAXIMUM SIDE WALL BEST PLACEMENT DO NOT INSTALL DO NOT INSTALL DEAD AIR NOT IN THIS AREA ANYWHERE IN THIS AREA 500mm 1000mm DEAD AIR ACCEPTABLE PLACEME...

Страница 8: ...chen alarm is desired it should have an ionisation alarm silencer feature or be a photoelectric alarm or heat alarm Do not place in the garage Mobile Home Installation For Well Insulated Mobile Homes...

Страница 9: ...derived from a square wave or modified square wave inverter These type of inverters are sometimes used to supply power to the structure in off grid installations such as solar or wind derived power so...

Страница 10: ...m failure to operate or electrical shock hazard Make certain alarms are wired to a continuous non switched final sub circuit NOTE Use approved listed Australian Standards cable 1 0mm TPS or larger as...

Страница 11: ...arts Do not tamper 1 Secure a suitable junction box near the position of the smoke alarm ensure the quick connect cable length is long enough to reach the junction box for termination to be made 2 Con...

Страница 12: ...nks once every 5 minutes and 20 seconds Mains power is present indicating normal operation Red LED Blinks once a second smoke alarm senses smoke and simultaneously sounds an audible alarm Red LED Blin...

Страница 13: ...ush Test button for at least five 5 seconds The smoke alarm will sound 3 long beeps pause 3 longs beeps repeating for up to 10 seconds after the Hush Test button is released NOTE If smoke alarms are i...

Страница 14: ...push the button on the initiating unit Red LED flashing every second to silence the alarm for up to 10 minutes If the smoke is not too dense that unit and all interconnected units will silence After...

Страница 15: ...ke alarm sounds unwanted alarms when residents are cooking taking showers etc 1 Hire an electrician to move smoke alarm to a new location See Section 3 Installation Instructions and Section 4 Location...

Страница 16: ...en installing the battery press the battery lever down into the battery compartment and install the battery See Figure 5 Caution If the battery compartment is closed without a battery the red battery...

Страница 17: ...electric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smouldering fires sooner than ionisation alarms Home fires develop in different ways and are often u...

Страница 18: ...o test your plan before an emergency You may not be able to reach your children It is important they know what to do Current studies have shown alarms may not awaken all sleeping individuals It is the...

Страница 19: ...t open it slightly and be ready to slam it shut if heat and smoke rush in Stay close to the floor if the air is smoky Breathe shallowly through a cloth wet if possible Once outside go to your selected...

Страница 20: ...come within guarantees that cannot be excluded under the ACL 5 2 The Customer is entitled to a replacement or refund for major failure and for compensation for other reasonably foreseeable loss or da...

Страница 21: ...make a claim If a defect in the product appears within the Warranty Period you are entitled to submit a warranty claim by first visiting the Garland website address below and filling out the Return F...

Страница 22: ...This warranty is provided by Madison Technologies 149 Beaconsfield St Silverwater NSW 2128 1800 66 99 99 www garlandcables com au ABN 56 010 669 379...

Отзывы: