TESTING & TROUBLESHOOTING
MP-GS-10/20 Troubleshooting Guide
Use this chart with the appropriate wiring diagram, also found in this manual
Mechanical Control
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Fan will not Run
No Power to Oven
Turn power on
No Power to Oven
Check Light circuit – IF OK, Select “Cook” and Check
Timer circuit . IF OK, Check Door Micro Switches
Micro switch not OPENING
Check connections & switch functions .
(Caution: the switch components on this control
system pass 115 v . a .c . through switch contacts .)
Fast Control
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Key Pad Buttons Not
Responding
Defective key pad
Use key pad diagnostics / pin outs test points
Loose ribbon connection at key pad
Check connection
PROBE ERROR in display
Faulty Probe
Replace probe
Loose probe connection
Check connections
HI TEMP In display
Oven at too high a temp for product
Allow oven to cool
HELP In display
Faulty Probe
Replace probe
Motor centrifugal switch stuck
Check centrifugal switch
Gas valve (s), or Ignition System
Check heat generation system – ( Refer to Service
procedures (Heat generation system) - .page
Unit will not shut off
Unit above 150°F
Put unit into cool down, open door slightly
No HIGH speed But LOW
speed works
Bad key pad
Use diagnostic KEY PAD TEST
Bad K2 relay on board
Check for voltage out of K2 relay
Bad motor
Check motor
No LOW speed But HIGH
speed works
Bad key pad
Use diagnostic KEY PAD TEST
Bad K2 relay on board
Check for voltage out of K3
Bad motor
Check motor
Display is BLANK NO
POWER
Bad transformer
Check for 24VAC out of TR1 transformer
Bad harness connection
Check connections
Unit will not heat
No power out of K4 relay
Check for power out of K4 relay
No power out of Ignition Module MV
Complete a flame current check to osolate
Gas valve shutoff switch open, PV, MV,
or both valves stuck closed
Check for MV power at gas shutoff switch, and that
PV and MV opens on call for heat
Motor centrifugal not closing
Check motor centrifugal switch
Motor stops, then after a
period of time comes back
on
Thermal Trip on motor
Inspect rear clearance
Motor air intake is clear of lint/debris
Replace motor
Содержание moisture+ MPGD10D
Страница 2: ...Part MPSM07 03 24 08 Page...
Страница 4: ...Part MPSM07 03 24 08 Page...
Страница 5: ...Part MPSM07 03 24 08 Page 5 Section One Operation Installation Manual...
Страница 38: ...Part MPSM07 03 24 08 Page 38...
Страница 39: ...Part MPSM07 03 24 08 Page 39 Section Two Service...
Страница 60: ...Part MPSM07 03 24 08 Page 60...
Страница 61: ...Part MPSM07 03 24 08 Page 61 Section Three Parts List...
Страница 62: ...Part MPSM07 03 24 08 Page 62 2006 Deluxe Control Panel Gas DELUXE CONTROL PANEL MOISTURE PLUS GAS...
Страница 66: ...Part MPSM07 03 24 08 Page 66 2006 Burners Gas Components BURNERS GAS COMPONENTS...
Страница 68: ...Part MPSM07 03 24 08 Page 68 Revised_Interior Componets Gas INTERIOR COMPONENTS MOISTURE PLUS GAS...
Страница 72: ...Part MPSM07 03 24 08 Page 72 Revised_Plumbing Components Gas DOOR COMPONENTS GAS MOISTURE...
Страница 74: ...Part MPSM07 03 24 08 Page 74 Revised_Exterior Components Gas EXTERIOR COMPONENTS GAS MOISTURE PLUS...
Страница 77: ...Part MPSM07 03 24 08 Page 77...
Страница 78: ...Part MPSM07 03 24 08 Page 78...
Страница 79: ...Part MPSM07 03 24 08 Page 79...
Страница 80: ......