Part # MPSM07 (03/24/08)
Page 53
TESTING & TROUBLESHOOTING
Component Readings
Spritzer
Solenoid
Valve Coil
Resistance
22
Ω
Dual Stage Gas
Valve
Solenoid
Resistance
Pilot Valve = 28 .5
Ω
Main Valve = 28
Ω
Fan Motor And Blower Wheel
The blower wheel and fan motor are considered to be one
complete assembly . Therefore, if the motor is determined to
require replacement, the blower wheel must be replaces as
well .
Garland sets the wheel at the factory with a specifi c gap
setting.
GROUND
5
LED
THS 2
M.V. 3
SENSE 4
Direct Spark
Ignition Module
3 Trials
4 Seconds Per Trial
No Retry
Minimum Acceptable
µa Reading
≥
0 .3
Heat & Control
Board Transformer
Primary = 21 .5
Ω
Secondary = 1 .5
Ω
Содержание moisture+ MP-ED-10-S
Страница 2: ...Part MPSM07 03 24 08 Page...
Страница 4: ...Part MPSM07 03 24 08 Page...
Страница 5: ...Part MPSM07 03 24 08 Page 5 Section One Operation Installation Manual...
Страница 38: ...Part MPSM07 03 24 08 Page 38...
Страница 39: ...Part MPSM07 03 24 08 Page 39 Section Two Service...
Страница 60: ...Part MPSM07 03 24 08 Page 60...
Страница 61: ...Part MPSM07 03 24 08 Page 61 Section Three Parts List...
Страница 62: ...Part MPSM07 03 24 08 Page 62 2006 Deluxe Control Panel Gas DELUXE CONTROL PANEL MOISTURE PLUS GAS...
Страница 66: ...Part MPSM07 03 24 08 Page 66 2006 Burners Gas Components BURNERS GAS COMPONENTS...
Страница 68: ...Part MPSM07 03 24 08 Page 68 Revised_Interior Componets Gas INTERIOR COMPONENTS MOISTURE PLUS GAS...
Страница 72: ...Part MPSM07 03 24 08 Page 72 Revised_Plumbing Components Gas DOOR COMPONENTS GAS MOISTURE...
Страница 74: ...Part MPSM07 03 24 08 Page 74 Revised_Exterior Components Gas EXTERIOR COMPONENTS GAS MOISTURE PLUS...
Страница 77: ...Part MPSM07 03 24 08 Page 77...
Страница 78: ...Part MPSM07 03 24 08 Page 78...
Страница 79: ...Part MPSM07 03 24 08 Page 79...
Страница 80: ......