Part # 4526029 (02/22/11)
Page 13
Measure
Activity
Comment
M41
•
Measure the resistance of coil temperature sensor resistor
at 25º Celsius (77º F) resistor will read 1kOhm
at 180º Celsius (356ºF) resistor will read 3,5kOhm
•
Resistor is higher on a higher temperature (PTC-resistor)
•
Replace sensor with a value less than 900Ohm
•
For a test: Short-out the sensor with a 1kOhm fi xed RESISTER
Disconnect sensing element
M50
•
Measure operational control or main power control switch with
potentiometer: Potentiometer is 10kOhm and linear
•
On level “0”: resistor = 0 Ohm
•
On maximum level resistance= 10kOhm
•
Resistor is proportional (linear) to swing angle
Disconnect operational control
(Poti)
M60
•
Measure temperature inside the case
•
Admissible ambient temperature: 0°C/32ºF to appr. 70°C/158ºF
•
Check point is on the CPU-circuit board
M100
•
Check connection cable for serial operational control and
CPU-circuit board
M101
•
Change serial operational control
M200
•
Check mains cable, perhaps one phase missing
•
Check the building fuses
M220
•
Disconnect ST2 on CPU-circuit board and measure resistance
between brown and blue,
Measured value: 200Ohm < R < 2kOhm
• Replace
rectifi er circuit board
M240
•
Use suitable pan material
•
Test with a pan with a diameter of 24cm (4.75”)
M241
•
Disconnect mains power supply
•
Visually inspect : blackened cables, components or strip
conductors?
•
Transistor module: measure internal diodes (UF = 0.4V)
• Rectifi er: measure internal diodes (UF = 0.5V)
•
Control trafo: measure electric voltage
•
Check power supply CPU-print +24V
CPU-circuit board ST1/1 and ST1/4 (24V +/- 1V)
M251
•
Check power switch on operational control