Garland G280-2 Скачать руководство пользователя страница 8

Part # 1382650 Rev 4 (12/07)

Page 8

INSTALLATION Continued

Pressure Regulators

1.  Must have a maximum regulation capacity for the total 

connected load.

2.  The pressure regulator(s) installed must be listed by a 

nationally recognized agency.

3.  The pressure regulator(s) must have a pressure 

adjustment range to allow adjustment to the manifold 

pressure on the appliance rating plate.

4.  Unless the manifold pressure on all connected appliances 

is the same, a separate pressure regulator must be 

supplied for each appliance(s) having differing manifold 

pressures.

5.  Gas supply lines may be connected at right, left or both 

ends of a battery or at the tee connections on spreader 

plates. If five (5) or more units are placed in a battery, 

more than one (1) supply line should be used. A readily 

accessible, approved type of hand shut-off valve should 

be installed on each supply line.

WARNING:  Local codes may require that the pressure 

regulator be externally vented. This will be supplied by 

others.

Testing

All fittings and pipe connections must be tested for 

leaks. Use approved gas leak detectors, soap solutions or 

equivalent, checking over and around the fittings and pipe 

connections. DO NOT USE A FLAME! Accessibility to all gas 

lines and fittings require that valve panel(s) lower front 

panel(s), oven rack(s) be removed. It may be necessary to 

remove or at least raise and securely prop griddles, hot 

tops and top grates. All parts removed (including fasteners) 

should be stored safely for re-use.

1.  Be sure that all valves and thermostats are in the ‘off’ 

position.

2.  Turn on the main gas supply valve.

3.  Leak test all valves and fittings as described in the 

procedure above. Correct any leaks required and recheck.

4.  Light oven pilot.

5.  The range is provided with an oven shut-off valve 

separate from the thermostat, turn this valve on and set 

the thermostat at 500°. If the range oven thermostat has 

an “off” position on the dial the thermostat is equipped 

with an internal, integral oven shut-off valve. Set this 

thermostat to 500°. In both cases, gas will now flow to the 

oven burner.

6.  Leak test all valves, fittings, etc. as above. Correct any 

leaks and retest.

7.  Shut off all range valves and set thermostat dials to ‘off’ or 

low position.

All units are tested and adjusted at the factory. However, 

burners and pilots should be checked at installation and 

adjusted if necessary.

Содержание G280-2

Страница 1: ...1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB3 1DQ ENGLAND Telephone 081 561 0433 Fax 081 848 0041 Part 1382650 Rev 4 12 07 2004 Garland Commercial Industries Inc FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVI...

Страница 2: ...ould expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of california to cause cancer Operation of this product could expose you to carbon monoxide if not adjusted properly Inhalation of carbon monoxide is known to the state of california to cause birth defects or other reproductive harm Keep appliance a...

Страница 3: ... Plate 6 Gas Supply 6 Installation for Ovens Equipped with Casters 7 Installation for Ovens Equipped with Legs 7 Ventilation and Air Supply 7 Assembly of Battery 7 Pressure Regulators 8 Testing 8 OPERATION 9 Oven Lighting Procedure All Models 9 CLEANING AND MAINTENANCE 9 Painted Finishes 9 Stainless Steel Finishes 9 Oven Interior porcelain enamel 10 Oven Interior optional continuous clean 10 OVEN ...

Страница 4: ...e T Modular Top INSTILLATION NOTES ShippingWt Lb Kg Combustible Wall Clearances Entry Clearances Operating Pressure M1R 480 220 M2S 480 220 Sides 6 152mm Back 6 152mm Crated 39 1 4 997mm Uncrated 34 1 4 870mm Natural 6 WC 15mbar Propane 10 WC 25mbar NOTE Installation clearance reductions are applicable only where local codes permit Data applies only to North America Gas input ratings shown here ar...

Страница 5: ...667mm 22 559mm 6 152mm 6 152mm 46 1168mm 34 864mm 535 243 NOTE Installation clearance reductions are applicable only where local codes permit This product is not approved for residential use Input Rating Nat Gas Operating Pressure Oven each Natural Propane BTU kW WC mbar WC mbar 30 000 8 78 4 5 11 10 25 Gas input ratings shown for installations up to 2000 ft 610m above sea level Please specify alt...

Страница 6: ... numbers and the warranty serial number The rating plate affixed to the unit contains this information We suggest installation maintenance and repairs should be performed by your local authorized service agency listed in your information manual pamphlet In the event you have any questions concerning the installation use care or service of the product write or call our Product Service Department Th...

Страница 7: ...y Proper ventilation is highly important for good operation The ideal method of ventilating a range is the use of a properly designed canopy which should extend six inches 6 beyond all sides of the appliance and six feet 6 six inches 6 from the floor A strong exhaust fan will create a vacuum in the room for an exhaust system vent to work properly replacement air must enter the room in which the ve...

Страница 8: ...tectors soap solutions or equivalent checking over and around the fittings and pipe connections DO NOT USE A FLAME Accessibility to all gas lines and fittings require that valve panel s lower front panel s oven rack s be removed It may be necessary to remove or at least raise and securely prop griddles hot tops and top grates All parts removed including fasteners should be stored safely for re use...

Страница 9: ...rgent and hot water Stubborn residue spots may be removed with a light weight non metallic scouring pad Dry thoroughly with a clean cloth NOTE Many parts of the commercial range are raw steel i e springs door hooks etc and can react to moisture forming rust This occurrence is normal and not considered a factory detect Clean with a stainless steel or fiber pad A coating of salt free oil may be appl...

Страница 10: ...urfaces be kept clean of excessive soiling due to spillage 2 How to put continuous cleaning action to work each day after baking and roasting operations have ceased empty the oven turn the temperature control up to high heat 500 This high heat will accelerate the cleaning action and reduce the time required to effectively clean the oven Usually the cleaning operation will take about 45 to 60 minut...

Страница 11: ... of pans or lower temperature Cakes have light outer color Raise temperature Cake settles slightly in the center Bake longer or raise oven temperature slightly Do not open doors to oven for long periods Cake ripples Overloading pans or batter is too thin Cakes are too coarse Lower oven temperature Pies have uneven color Reduce number of pies per rack or eliminate use of bake pans Cupcakes crack on...

Страница 12: ......

Отзывы: