background image

Part # 4521635 (03/04/08)

Page 1

GARLAND COMMERCIAL INDUSTRIES

185 East South Street

Freeland, Pennsylvania 18224

Phone: (570) 636-1000

Fax: (570) 636-3903

GARLAND COMMERCIAL RANGES, LTD.

1177 Kamato Road, Mississauga, Ontario L4W 1X4

CANADA

Phone: 905-624-0260

Fax: 905-624-5669

Enodis UK LTD.

Swallowfield Way, Hayes, Middlesex UB3 1DQ ENGLAND

Telephone: 081-561-0433

Fax: 081-848-0041

Part # 4521635 (03/04/08)

© 2006 Garland Commercial Industries, Inc.

SERVICE MANUAL

INDUCTION COOKERS WITH RTCS TECHNOLOGY

(REAL TIME TEMPERATURE CONTROL SYSTEM

COUNTER TOP/BUILT IN/WOK MODELS

IMPORTANT NOTE:

 

INDUCTION COOKERS MANUFACTURED WITH RTCS TECHNOLOGY WILL HAVE  

FIVE DIGITS IN THE CENTER OF THE SERIAL NUMBER: EXAMPLE: BA06.00001.0505

MODELS

GIU 1.5 (BH/BA 1500)
GIU 1.8 (BH/BA 1800)
GIU 2.5 (BH/BA 2500)
GIU 3.5 (SH/BA 3500)
GIU 5.0 (SH/BA 5000)

GIU 2.5 BI (BH/IN 2500)
GIU 3.5 BI (SH/IN 3500)
GIU 5.0 BI (SH/IN 5000)

GIWOK 3.5 (SH/WO 3500)
GIWOK 5.0 (SH/WO 5000)

GIWOK 3.5 BI (SH/WO/IN 3500)
GIWOK 5.0 BI (SH/WO/IN 5000)

SA

NITATION

LISTED

CM

86037

C

Содержание Enodis GIU-1.5 (BH/BA 1500)

Страница 1: ...land Commercial Industries Inc SERVICE MANUAL INDUCTION COOKERS WITH RTCS TECHNOLOGY REAL TIME TEMPERATURE CONTROL SYSTEM COUNTER TOP BUILT IN WOK MODELS IMPORTANT NOTE INDUCTION COOKERS MANUFACTURED...

Страница 2: ...tallic Plates 6 Power Rating 7 Fan 7 Test Of The Components 7 Rectifier 7 Transistor module IGBT 8 CU RTCS Sensors 8 Potentiometer 8 SECTION 5 MAINTENANCE SERVICE 9 SECTION 6 FAULT FINDING 12 General...

Страница 3: ...as all inspections are performed by authorized and qualified personnel Before attempting to operate the equipment carefully read the information and instructions outlined in the Installations and Oper...

Страница 4: ...rrent A max 16 14 5 max 16 Power factor Cos 0 95 0 95 0 95 Discharge rate mA 4 4 4 Coil mm 190 7 5 190 7 5 190 7 5 Model SH IN Built in Models 208 V 1 Ph 240 V 1 Ph 208 V 3 Ph Wattage kW 3 5 kW 3 5 kW...

Страница 5: ...sition of the control knob to 0 and then to the required power level See Error Message Section 6 Power board The temperature of the power board is checked by a temperature sensor As soon as the heat s...

Страница 6: ...the material structure of the pan or its efficiency In some cases the magnet will attach itself to the bottom of the pan however the pan may not be suitable for use with induction cooking Always use...

Страница 7: ...at 2 Measure the time until the fan starts working 9 12 The fan should start working after 6 8 minutes 3 Go on cooking for about 30 minutes 9 12 The heating process may periodically be interrupted for...

Страница 8: ...rt circuit or an interruption the IGBT transistor is defective and must be replaced CU RTCS Sensors CU Sensor 1 Center 4 5 5 Ohms CU Sensor 2 Outer 4 5 5 Ohms The two CU sensors are mounted directly o...

Страница 9: ...once a year The following routine maintenance should and must be completed periodically Fan Function of the cooker can only be guaranteed if all electronic components are operated within their normal...

Страница 10: ...ot make contact with the high voltage section on the power board Coil wires must be tightly twisted together and precisely placed Coil terminals must be connected in the direction shown in photo Gener...

Страница 11: ...Incorrect Coil Spoil Connections Coil wires not twisted tightly together or precisely placed Coil terminals connected in the incorrect direction Coil terminals connected in the incorrect direction Co...

Страница 12: ...code 1 8 The indicator lamp located directly above the control knob flashes for an interval of 0 6 seconds The number of the following short flashes have to be counted in order to determine the type...

Страница 13: ...ms at 25 C 77 F 19 CU sensor 2 high temperature warning a Temperature of the cooking field too high b Turn the power down 20 Power reduction generator inside temperature a Check for heat sources aroun...

Страница 14: ...K Check electric Potential DC Volts Defective Check IGBT Transistor s Replace Power board Error Check fuse T1A OK Check power Print board visually Check wiring Error Correct wiring connections Wired i...

Страница 15: ...ht side Lift cover with the glass Remove M4 screws remove coil carrier Remove PT sensor and coil connections SECTION 8 ADJUSTMENT OF PROCESS PARAMETERS The induction unit excluding all WOK units with...

Страница 16: ...TE When replacing the power board and or induction coil with RTCS sensors you must reset all parameters IMPERATIVE Pay close attention to whether you receive a feedback signal from the PC or Laptop af...

Страница 17: ...tector with the key On the console appears the message please confirm Press the key again The following message appears on the monitor save pan detector limit 9 By input the mode of adjustment will be...

Страница 18: ...60006 SH BA 3500 240VAC 1N 3 5kW GIU 3 5 185 23 99560007 SH BA 5000 208VAC 3N 5kW GIU 5 0 167 21 99560008 SH BA 5000 400VAC 3N 5kW GIU 5 0 99560009 SH BA 5000 440VAC 3N 5kW GIU 5 0 99580004 SH IN 3500...

Страница 19: ...laptop computer Place the IR sensor section onto the ceran glass towards the bottom left hand corner for counter top cookers Position the IR sensor to the generator Refer to figure 3 in this section...

Страница 20: ...ld be saved so that there will be no need to put them again and the connection can be built up by selecting symbol IR2400 ht Figure 3 IR Adapter position for counter top base line cookers For all coun...

Страница 21: ...ter position for built in install line cookers IR Adapter to be positioned directly over rectangular opening shown in photo IR Adapter tool in position Place Wok Bowl top assembly back onto cooker as...

Страница 22: ...CHEMATIC Main Power Filter L1 L2 L3 PE 230V L2 208V L2 240V L2 AC DC Power Supply 12VAC 24VDC 5VDC 5VDC GND Rectifier AC DC 12VAC 5VDC 24VDC T B 24VDC Potentiometer LED IR Adapter Fan CPU IGBT Transis...

Страница 23: ...Part 4521635 03 04 08 Page 23...

Страница 24: ......