Part # 4521635 (03/04/08)
Page 16
• Place short circuit service plug into the power print board
across the (Poti-LED) as showed in the photo below.
• Connect the induction unit to the main power supply.
• The CU sensors initialize automatically.
• After successful initialization, the green LED on the small
CPU-print (board) illuminates.
• In case the system finds an error during initialization, the
red LED will illuminate.
• Disconnect the induction unit from the main power
supply.
• Check the CU sensors at the plug by means of the Ohm
meter.
• Re-start the procedure of initialization.
• Disconnect the unit from the main power supply.
• Remove the short circuit service plug from both the Poti
and LED connections.
Initializing The Induction Unit
By PC Or Laptop
The initialization of the CU (RTCS) sensors (
excluding all
WOK models)
, as well as adjustments of the pan detection
and power performance, can be performed by means of
the hyperterminal program. Please refer to Section 9 “
IR
Interface
” for instructions on how to use the hyperterminal
program The following adjustments must be done in the
hyperterminal program: 2400bps, 8bit, no parity, 1 stop bit,
hardware protocol.
IMPORTANT NOTE
: When replacing the power board and
or induction coil with RTCS sensors, you must reset all
parameters.
IMPERATIVE!
Pay close attention to whether you receive a
feedback signal from the PC or Laptop after every change.
This will be your signal that the change has been accepted
successfully.
12345 Entry to the mode of adjustment (password)
;
Initialize Cu sensor (temperature of the coil ca.
25°C/77°F) excluding WOK.
N
Increase the limit of the mains current (+)
n
Decrease the limit of the mains current (-)
“
Save the limit of the mains (power) current
T
Increase pan detector (+)
t
Decrease pan detector (-)
=
Save pan detector
-?
Leave the mode of adjustment
.
State software version
Change Of The Parameters
1. Connect the RS232 connection cable to the
PC/Laptop and straighten the IR-adapter to the left lower
corner of the ceran glass. For counter top cookers, refer to
Section (9) figure #3 for correct IR adapter positioning. For
all Wok cookers, you will be required to remove the top
wok bowl assembly. Place the IR-adapter in the left hand
corner directly over the rectangular opening located on
the metal sheet with ferrit stripes. Please refer to Section
(9) figure #4 for Wok cooker IR adapter positioning.
2. Start HT2400 (see chapter 9) and turn unit on!
3. Input “
12345
” and the mode of adjustment will now
begin. The following message will appear on the monitor:
IR= On
WELCOME REPAIRMEN