GB
- 17 -
11. Troubleshooting
Fault
Possible cause
Remedy
The motor does not
start
- Power failure
- Motor circuit breaker has been trig-
gered
- The switch for selecting the direc-
tion of rotation is in its center positi-
on.
- Check the mains lead, plug and
fuse.
- Press the Reset button (see point
6.4)
- Set the direction of rotation on the
switch
Material is not
drawn in by the
shredder
- The shredding blade is running in
reverse.
- Material blockage in the
fi
lling fun-
nel
- The shredding blade is jammed
- Change the direction of rotation.
- Change the direction of rotation
and pull the material out of the fun-
nel. Feed in thick branches again
so that the blade does not immedi-
ately engage again in the notches it
previously cut.
- Change the direction of rotation.
The blade will now release the jam-
med material.
The material is not
shredded properly
- The counter blade is not set cor-
rectly.
- Adjust the counter blade. See sec-
tion 6.6 on how to do so.
Anl_GLH_E_2540_SPK7.indb 17
Anl_GLH_E_2540_SPK7.indb 17
19.05.15 08:44
19.05.15 08:44
Содержание GLH-E 2540
Страница 105: ...BG 105 9 10 5 30 C Anl_GLH_E_2540_SPK7 indb 105 Anl_GLH_E_2540_SPK7 indb 105 19 05 15 08 44 19 05 15 08 44...
Страница 106: ...BG 106 11 1 2 6 4 6 6 Anl_GLH_E_2540_SPK7 indb 106 Anl_GLH_E_2540_SPK7 indb 106 19 05 15 08 44 19 05 15 08 44...
Страница 108: ...BG 108 www isc gmbh info Anl_GLH_E_2540_SPK7 indb 108 Anl_GLH_E_2540_SPK7 indb 108 19 05 15 08 44 19 05 15 08 44...
Страница 139: ...RU 139 11 1 2 6 4 6 6 Anl_GLH_E_2540_SPK7 indb 139 Anl_GLH_E_2540_SPK7 indb 139 19 05 15 08 44 19 05 15 08 44...
Страница 141: ...RU 141 www isc gmbh info Anl_GLH_E_2540_SPK7 indb 141 Anl_GLH_E_2540_SPK7 indb 141 19 05 15 08 44 19 05 15 08 44...
Страница 208: ...EH 05 2015 01 Anl_GLH_E_2540_SPK7 indb 208 Anl_GLH_E_2540_SPK7 indb 208 19 05 15 08 44 19 05 15 08 44...