background image

Spare Parts Overview 

22 

4000481-04 

8.2.1 

Part list MPC 301 Zp Ex 

Item 

no. 

Designation 

Piece 

Order no. 

Basic pump 

consisting of position: 1 

– 9 

(only completely available)

 

400733-03 

  1 

  - Three-phase asynchronous motor 
    Ex II 2G EEx de IIC T4 
    400 V; 50 Hz; 0.18 kW 

826441 

  2 

  - Pump casing 1 

400640-01 

  3 

  - Flywheel mass 

400649-01 

  4 

  - Eccentric cam  

400648 

  5 

  - Close tolerance spacer 25 x 35 x 1 

824957-1 

  6 

  - Ball bearing with piston rod 

400647-01 

  7 

  - Mass balance 

400678 

  8 

  - Covering 

400641-01 

  9 

Connection head 

400901 

10 

PTFE insert 

400902 

11 

Valve 

400656 

12 

O-Ring EPDM, ø 25 x 2 

829250-1 

13 

Pump head 

400705-02 

14 

Tightening washer 

400707 

15 

Diaphragm 

400732 

16 

Pressure washer 

400680 

17 

Manifold 1 

400905 

18 

Straight threaded joint with seal edge PVDF, 10 

– ¼“ 

829931 

19 

Hose nozzle, stainless steel, DN 8 

– G¼“ 

710798-3 

20 

Vacuum hose PTFE, 10 / 8x1 mm 

0.2 m 

828332 

21 

O-Ring EPDM, ø 12 x 2 

829217-3 

22 

Handle 

828634 

23 

Foot 

400900 

24 

Rubber metal-pad 30x36 

829138 

25 

Washer 

112538 

Содержание WELCH MPC 301 Zp Ex

Страница 1: ...nual EN Translation of the german original manual Diaphragm pumps in an explosion proof design Models MPC 301 Zp Ex II 2G c IIB T4 X 10 C Ta 40 C MPC 601 Tp Ex II 2G c IIB T4 X 10 C Ta 40 C 4000481 04...

Страница 2: ...permission of Co Gardner Denver Thomas GmbH All rights under the copyright laws are expressly reserved by Co Gardner Denver Thomas GmbH We reserve the right to make changes and amendments Gardner Denv...

Страница 3: ...Pressure Pumping Speed Diagrams 12 4 3 Device Data 13 5 Installation and Operation 14 5 1 Unpacking 14 5 2 Installation and Connection 14 5 3 Operation 14 5 3 1 Start up 15 5 4 Storage 15 5 5 Scrap Di...

Страница 4: ...competence required to perform the work that has to be done The user must authorize the operating personnel to do the work that has to be done The personnel must have read and understood the complete...

Страница 5: ...General requirements DIN EN 61000 6 2 2011 06 DIN EN 61000 6 4 2011 09 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments Part 6 4 Generic standards Emi...

Страница 6: ...stems Improper use can lead to injuries or material damage Observe the following instructions Only operate the diaphragm pumps with hoses of the specified dimensions The absolute pressure generated at...

Страница 7: ...tact with the gases Poisonous gases Use a separator when pumping poisonous or harmful gases Prevent such substances from leaking out of the appliance or pump Treat these substances according to the ap...

Страница 8: ...aphragms in stroke movement This changes the size of the space between the diaphragms and pump head pump chamber Increasing the size of the pump chamber opens the inlet valve while the outlet valve is...

Страница 9: ...Ultimate pressure Model 2 mbar MPC 601 Tp Ex Note The three stage model of the diaphragm pump is fitted with a by pass and a non return valve parallel to the second and third stages These serve to re...

Страница 10: ...combustible gases vapors and mists in any mix ratio that are to be pumped or which are ambient are determined according to the specifications of standard EN 13 463 1 The diaphragm pumps mentioned here...

Страница 11: ...nominal units It is believed to be accurate and reliable and is offered as and aid to help in the selection of products It is the responsibility of the user to determine the suitability of the produc...

Страница 12: ...Technical Data 12 4000481 04 4 2 Intake Pressure Pumping Speed Diagrams Fig 4 Intake Pressure Pumping Speed Diagram Model MPC 301 Zp Ex Fig 5 Intake Pressure Pumping Speed Diagram Model MPC 601 Tp Ex...

Страница 13: ...ing gas temperature measured on the inlet of the vacuum pump C 60 60 Bearing maintenance free maintenance free Reference surface sound pressure level DIN EN ISO 2151 dB A 44 44 Rated speed 1 min 1415...

Страница 14: ...ble to simultaneously detect a malfunction and initiate suitable actions to prevent possible damage 5 3 Operation Observe the basic safety instructions when using the pump Contents of the currently va...

Страница 15: ...ity 90 Leave the protective elements on the suction and pressure ports Another equally good protection may be used 5 5 Scrap Disposal CAUTION The Diaphragm pumps must be disposed of in accordance with...

Страница 16: ...be performed outside the areas at risk of explosion The pump must be disconnected from the power supply before maintenance work starts WARNING Only perform the work that is described here and that whi...

Страница 17: ...ssary Wear protective gloves Parts must be renewed at the intervals stated in this Operating Manual or as speci fied by the user internally Do not clean with compressed air 6 2 2 Assembly see Fig 6 1...

Страница 18: ...ation may only be performed by the manufacturer or authorized workshops WARNING The user shall be liable for the consequences of an incorrect damage report or a contaminated pump The statements in the...

Страница 19: ...y Vacuum pump leaking Check the hose connections between the pump heads replace the hoses and or fittings if necessary Pump head leaking Service workshop Repair and or exchange Diaphragm defective Use...

Страница 20: ...ber CAUTION We are not liable for any damage caused by the installation of any parts not supplied by the manufacturer 8 1 Service kit Designation Order no for MPC 301 Zp Ex MPC 601 Tp Ex Service kit 4...

Страница 21: ...Spare Parts Overview 4000481 04 21 8 2 Diaphragm pump MPC 301 Zp Ex Fig 7 Exploded view MPC 301 Zp Ex...

Страница 22: ...Ball bearing with piston rod 2 400647 01 7 Mass balance 1 400678 8 Covering 1 400641 01 9 Connection head 2 400901 10 PTFE insert 2 400902 11 Valve 4 400656 12 O Ring EPDM 25 x 2 4 829250 1 13 Pump he...

Страница 23: ...Spare Parts Overview 4000481 04 23 8 3 Diaphragm pump MPC 601 Tp Ex Fig 8 Exploded view MPC 601 Tp Ex...

Страница 24: ...on head 4 400901 11 PTFE insert 4 400902 12 Valve 8 400656 13 O Ring EPDM 25 x 2 8 829250 1 14 Pump head 4 400705 02 15 Tightening washer 4 400707 16 Diaphragm 4 400732 17 Pressure washer 4 400680 18...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...Teil 1 Grundlagen und Anforderungen Non electrical equipment for use in potentially explosive atmospheres part 1 Basic method and requirements Appareils non lectriques destin s tre utilis s en atmosph...

Отзывы: