13-18-606 Page 46
In case the drain valve is fouled with dirt, cleanse the collection bowl:
1. Be sure the unit is completely off and oil sump is depressurized.
2. Disconnect, lockout and tagout power supply to the compressor package.
3. Close (when provided) valve isolating compressor package from air system.
4. Unscrew drain valve (1) from isolation valve (5).
5. Unscrew collection bowl (3) from separator housing (4).
6. Inspect and cleans collection bowl and sealing o-ring.
7. Reinstall in reverse order.