13-18-606 Page 22
Next, press the Enter
button to access the Adjustment Menu tree
Since the Target Pressure setting is under the Operation Adjustment menu, press Enter
again to
access that sub-menu
The Target Pressure is the second item in the Operation Adjustment sub-menu so press the Down
button to navigate to the Target Pressure setting.
To change the Target Pressure, press the Enter
button to edit the value.
A flashing cursor will appear covering the least significant digit in the Target Pressure value, use the Plus
and Minus
buttons to change its value. Use the Right
and Left
buttons to move the
cursor to other digits in the Target Pressure value. When the desired Target Pressure value is displayed,
press the Enter
button to save the new value. Pressing the Stop/Reset
button will abort the
change and restore the previous value.
In order to save the changes made to parameters, press the Stop/Reset button to go back to the heading
of the current menu and then press the Stop/Reset button again. If parameter changes have been made,
the following screen will appear.
To permanently save the changes that were made, press the Enter
button. If the Stop/Reset
button is pressed, the parameter changes will be lost the next time the compressor power is turned off.
ADJUSTMENT MENU
OPERATION ADJUSTMENT
(SELECT SUB MENU)
OPERATION ADJUSTMENT
LANGUAGE-LANGUAGE
ENGLISH (US)
(SELECT PARAMETER)
OPERATION ADJUSTMENT
TARGET PRESSURE
100 PSI
(SELECT PARAMETER)
OPERATION ADJUSTMENT
TARGET PRESSURE
100 PSI
(EDIT PARAMETER)
STORE MODIFIED
PARAMETERS?
STOP = NO
ENTER = YES
Содержание VS-11
Страница 10: ...13 18 604 Page 9 Figure 1 2 PACKAGE OUTLINE AIR COOLED 300CGA804 A Ref Drawing Page 1 of 2...
Страница 11: ...13 18 604 Page 10 Figure 1 3 PACKAGE OUTLINE AIR COOLED 300CGA804 A Ref Drawing Page 2 of 2...
Страница 12: ...13 18 604 Page 11 Figure 1 4 PACKAGE OUTLINE AIR COOLED TANK MOUNTED 301CGA804 A Ref Drawing Page 1 of 2...
Страница 13: ...13 18 604 Page 12 Figure 1 5 PACKAGE OUTLINE AIR COOLED TANK MOUNTED 301CGA804 A Ref Drawing Page 2 of 2...
Страница 28: ...13 18 606 Page 27 Figure 4 1 ELECTRICAL ENCLOSURE HARDWARE 302CGA810 D Ref Drawing...
Страница 31: ...13 18 606 Page 30 Figure 4 2 PIPING AND INSTRUMENTATION ILLUSTRATION 300CGB797 B Ref Drawing...
Страница 67: ......