manualshive.com logo in svg
background image

 

HYD-7-600    Page  7 

SECTION 1 
EQUIPMENT CHECK

 

 
Before uncrating, check the packing slip carefully to be sure all the parts have been received.  All 
accessories are listed as separate items on the packing slip, and small important accessories such as 
relief valves can be overlooked or lost.  After every item on the packing slip has been checked off, 
uncrate carefully.  Register a claim with the carrier for lost or damaged equipment. 
 
 

 

Customers are cautioned to provide adequate protection, warning and safety equipment 
necessary to protect personnel against hazards involved in installation and operation of this 
equipment in the system or facility. 

 

STORAGE 

 
Your Gardner Denver® Hydrapak was packaged at the factory with adequate protection to permit normal 
storage for up to six (6) months. 
 
If the unit is to be stored under adverse conditions or for extended periods of time, the following additional 
measures should be taken to prevent damage. 
 

1. 

Store the cooler in a clean, dry, heated (if possible) area. 

 

2. 

Make certain inlet and discharge air ports are tightly covered to prevent foreign material from 
entering the hydraulic system. 

 

3. 

All hydraulic fittings are zinc coated but should also be protected against rust and corrosion. 

 

4. 

In high humidity or corrosive environments, additional measures may be required to prevent 
corrosion of an hub and aluminum control block. 

 
 

Содержание MH-C2 HYDRAPAK

Страница 1: ...PARTS LIST OPERATING AND SERVICE MANUAL MOBILE HYDRAULIC COOLING SYSTEM 30 G P M 3500 PSI 5000 PSI optional HYD 7 600 Version 01 September 17 2014 MH C2 HYDRAPAK...

Страница 2: ......

Страница 3: ...e 3 Maintain Hydrapak Reliability And Performance 4 Instructions For Ordering Repair Parts 4 Foreword 5 Safety Instructions 6 Section 1 Equipment Check 7 Section 2 Installation 8 Section 3 Initial Sta...

Страница 4: ...e Section 3 12 Installation Section 2 8 Introduction Your Key To Trouble Free Service 3 Maintenance Section 4 13 Mounting 8 Parts List Section 5 14 Safety Instructions 6 Storage 7 Warranty 16 LIST OF...

Страница 5: ...must observe to assure optimum cooler performance There is no guesswork in the manufacture of your highly advanced Gardner Denver Hydrapak and there must be none in preparing the cooler to get the job...

Страница 6: ...our state of the art factory under exacting quality standards Your AUTHORIZED DISTRIBUTOR offers all the backup you require A worldwide network of authorized distributors provides the finest product...

Страница 7: ...tion for day to day operation maintenance and adjustment Careful adherence to these instructions will result in economical operation and minimum downtime Danger indicate a hazardous situation that if...

Страница 8: ...eath If injured seek emergency medical help immediately Immediate surgery is required to remove oil Do not use finger or skin to check for leaks Lower load and or relieve hydraulic pressure before loo...

Страница 9: ...ion and operation of this equipment in the system or facility STORAGE Your Gardner Denver Hydrapak was packaged at the factory with adequate protection to permit normal storage for up to six 6 months...

Страница 10: ...uum at the hydraulic pump inlet is 5 Hg For gear pumps and 2 Hg for piston pumps The suction hose must be capable of operating under 28 Hg Vacuum Special attention should be given to applications util...

Страница 11: ...allation of the hoses should include a slight bend in the hoses near the connections This allows them to flex reduce vibration stress and hose shrinkage under load 5 All hoses should use the largest b...

Страница 12: ...HYD 7 600 Page 10 FIGURE 2 1 AIR FLOW DIRECTION AND OUTLINE...

Страница 13: ...HYD 7 600 Page 11 FIGURE 2 2 AIR FLOW DIRECTION AND OUTLINE...

Страница 14: ...reservoir with Shell Tellus T series ISO 32 hydraulic oil or equivalent until oil appears in sight glass 3 Replace filter element and cap 4 Slowly raise clutch while engine is running to engage P T O...

Страница 15: ...l level each week with system OFF Oil should be visible in lower of sight glass 3 Visually check the system each week all fittings hoses and Hydrapak mounting 4 Grease P T O Pump spline every 3 months...

Страница 16: ...HYD 7 600 Page 14 SECTION 5 PARTS LIST MH C2 See page 15 for Parts List...

Страница 17: ...ALVE 1 303000008 303000008 BB1132940 25 FITTING HYD ADAPTER 1 302065207 302065207 302065207 26 FITTING HYD TEE 1 302005200 302005200 302005200 27 FAN 1 VP1118078 VP1118078 VP1118078 28 FITTING HYD PLU...

Страница 18: ...e personnel is not provided for by this warranty Transportation of Company s choice within the continental United States is covered by this warranty for replacement of any blower which in the Company...

Страница 19: ......

Страница 20: ...For additional information contact your local representative or visit www contactgd com blowers 2014 Gardner Denver Inc Printed in U S A...

Отзывы: