L110 RS,
50Hz + 60Hz, air-cooled "A" + water-cooled
"W"
L110 RS,
Cooling water inlet temperature
"W" [°C]
min. 5 / max. 35
Cooling water outlet temperature
"W" [°C]
max. 55
Cooling water pressure
"W" [bar]
max. 10
Cooling water connections
"W"
EN 10226-1 Rp 11/4 (DIN 2999-R 1 1/2)
Total oil quantity
[l]
63
Compressed air connection
EN 10226-1 R 2 1/2 (DIN 2999-R 2 1/2)
Weight
[kg]
"A" = 2604
"W" = 2430
Dimensions L x W x H
[mm]
2290 x 1327 x 2039
Chart 9-8: Technical data; L110 RS, 50Hz + 60Hz, air-cooled "A", water-cooled "W"
*)
Data measurement and specification as per ISO1217 fourth edition, Appendix C & E and under the following con-
ditions:
Air suction pressure: 1 bar a / 14.5 psia
Air suction temperature: 20°C / 68°F air humidity: 0% (dry)
**)
Measured in an open area as per ISO 2151, tolerance 3 dB(A).
At CompAir, our philosophy is to continually improve our products. We therefore reserve the right to alter technical
data without prior notice.
9.6.7
L132 RS, 50Hz + 60Hz, air-cooled "A", water-cooled "W"
L132 RS,
50Hz + 60Hz, air-cooled "A" + water-cooled
"W"
L132 RS,
Maximum operating pressure
[bar]
13.0
Minimum operating pressure
[bar]
5.0
Ambient temperature
[°C]
1 / 45
min speed
max. speed
Volume flow / Disch. Pressure [7.5 bar]
*)
[m
3
/min]
5.27
24.34
Volume flow / Disch. Pressure [9 bar]
*)
[m
3
/min]
5.24
22.44
Volume flow / Disch. Pressure [10 bar]
*)
[m
3
/min]
5.19
21.19
Volume flow / Disch. Pressure [13 bar]
*)
[m
3
/min]
6.15
18.40
Aftercooler outlet temperature above ambient
temperature
"A" = [°C]
"W" = [°C]
8
9
Sound pressure level (ISO 2151)
**)
"A" [dB(A)]
"W" [dB(A)]
74 / 77 (50Hz) ; 75 / 78 (60Hz)
74 / 77 (50Hz) ; 75 / 78 (60Hz)
Rated speed of drive motor
[kW]
132
Total current consumption during load operation
(380V) / (400V) / (460V)
"A" [A]
"W" [A]
268 / 252 / 221
258 / 245 / 213