L90-L110
60Hz, air-cooled "A” + water-
cooled "W"
L90
L110
Total current consumption during load
operation (380V / 460V)
[A]
205 / 166
247 / 201
Electric motor
IP55 (IE3) - IEC 60034-2-1 ECA Qualifying
Rated speed of drive motor
[rpm]
3000
Rated speed of fan motor
"A" [kW]
W" [kW]
2.6
0.66
6.6
0.66
Recommended cable cross-section
(380V / 460V)
[mm
2
]
3 x 70 PE35
3 x 95 PE50 /
3 x 70 PE35
Recommended fuse rating (time-
delayed) (380V + 460V)
[A]
3 x 224 / 3 x 200
3 x 300 / 3 x 224
Cooling air volume flow
"A" [m
3
/min]
197
197
Cooling air volume flow
"W" [m
3
/min]
100
Cooling air outlet temperature above
ambient temperature
"A" [°C]
28
28
Residual pressure at ambient temper-
ature
"A" [Pa]
90/ 70
[35 °C / 45 °C]
90/ 70
[35 °C / 45 °C]
Cooling water quantity
"W" [l/min]
90
@ ΔT = 17K
@ Δp = 0.8 bar
125
@ ΔT = 14K
@ Δp = 1.4 bar
Cooling water inlet temperature
"W" [°C]
min. 5 / max. 35
Cooling water outlet temperature
"W" [°C]
max. 55
Cooling water pressure
"W" [bar]
max. 10
Cooling water connections
"W"
EN 10226-1 Rp 11/4 (DIN 2999-R 1 1/2)
Total oil quantity
[l]
63
Compressed air connection
EN 10226 R 2 1/2 (DIN 2999-R 2 1/2)
Weight
[kg]
"A" = 2447
"W" = 2311
"A" = 2532
"W" = 2396
Dimensions L x W x H
[mm]
2290 x 1327 x 2039
Chart 9-4: Technical Data; L90-L110 , 60Hz, air-cooled "A", water-cooled "W”
*)
Data measurement and specification as per ISO1217 fourth edition, Appendix C & E and under the following con-
ditions:
Air suction pressure: 1 bar a / 14.5 psia
Air suction temperature: 20°C / 68°F air humidity: 0% (dry)
**)
Measured in an open area as per ISO 2151, tolerance 3 dB(A).
At CompAir, our philosophy is to continually improve our products. We therefore reserve the right to alter technical
data without prior notice.