Maintenance plan: Maintenance every 125 operating hours
Component
Measure
Necessary qualification Carried out
Cooler / fan
Check and clean if nec-
essary
Maintenance personnel
Oil tank
Drain condensate
Maintenance personnel
Chart 8-2: Maintenance plan, very 125 operating hours
Maintenance plan: Service interval A - every 2000 hours run, but no less than annually
Component
Measure
Necessary qualification Carried out
Filter mats cooling air inlet
Check, clean and replace as
necessary.
Maintenance personnel
Air filter
Replace air filter
Maintenance personnel
Oil filter
Replace oil filter
Maintenance personnel
Condensate drain
Aftercooler, function check.
Maintenance personnel
Electronic control unit
Check for displayed mainte-
nance requirements.
Operator
Chart 8-3: Maintenance plan: Service C
Maintenance plan: Service interval B – Every 4,000 hours, but no less than annually
Component
Measure
Necessary qualification Executed
Customer operations log
Check and adhere to operat-
ing parameters.
Operator
Electronic control unit
Check fault statistics.
Operator
General
Maintenance / cleaning
Maintenance personnel
Oil fine separator
Replace
Maintenance personnel
Switch cabinet cooling air inlet
filter
Replace.
Maintenance personnel
Frequency converter cooling
air inlet filter (RS)
Replace.
Maintenance personnel
FLUIDFORCE SCREW WAR-
RANTY LUBRICANT com-
pressor oil
Replace
Maintenance personnel
Moisture sensor replacement
filter cap (RS) + e
Replace
Maintenance personnel
Motor bearing lubrication
Replace LC unit cartridge
(grease cartridge)
Maintenance personnel
Safety valve
Function test at least once a
year
Maintenance personnel
Hoses and pipelines
Check for leaks or as the case
may be, damage.
Maintenance personnel
Electrical wiring
Check connections and condi-
tion.
Electrician
Compressor
Maintain the compressor room
and surroundings clean.
Operator
Chart 8-4: Maintenance plan: Service D