Lubrication
The GD150 is supplied complete with sealed greased bearings which should
not need re-lubricating within the normal life of the machine.
3.3
Lifting
The weight of the compressor without ancillaries is 32 kg and we
recommend that the machine is lifted with a suitable sling. The machine
must be supported/lifted under the main body and not by the plastic cowls
Any equipment used for lifting the machine should be rated accordingly.
3.4
Mounting orientations
The GD150 can be installed on any of the 4 mounting faces shown below
and can be driven in both rotations by using either end of the input shaft.
Additionally, the mounting brackets can be fitted facing inwards or outwards
increasing the total fitting positions and hole centre positions available.
The machine has the inlet and discharge flanges on the same face to simplify
connection and routing of pipe work.
Figure 4. Mounting & Drive options
Only lift/support the machine
using the main body and not
the plastic cowls.
CAUTION
Outlet
Inlet