Page 6
4990616006 Date: 06/16
GD150 Installation, Operating & Maintenance Manual
2.4 Dimensions, Performance Data & Operating
Environment
Dimensions
The dimensions of the compressor are shown in figure 2 below.
Performance
The performance details and power requirements of the GD150 compressor
are shown on the product data sheet.
For additional information, the constant running torque does not exceed:
56 Nm
Speed range 1000 - 1600 rpm
Operating environment
The permissible/foreseen operating environment is as follows:
Figure 2. Dimensions
General
244
92
40
PORT DETAIL
SHAFT DETAIL
8
¯25
¯68
¯32
180
230
80
80
125
120
40
40
5
18
¯12
174
265
195
509
120
120
141
59
Ambient temperature range
-40 to +50°C
Resistant to tropical rain (in operation and transit), salt and sun
Humidity level
Up to 100% RH condensing
Vibration level
0 to 40 Hz; ± 40 mm amplitude tested.
Inlet depression
Not to exceed 50 mbar
Orientation
See fig 4 page 8
Max. outlet temperature
220°C