- 11 -
G
11
G
1
G
5
G
51
G
3
G
21
G
2
Y
3
21
20
H
2
H
1
Y
5
Y
55
S
21
S
2
S
11
S
1
R
EPAIR
I
NSTRUCTIONS
1. Removal and Re-assembly of Water
Jacket
(fi g. 12, 13 and data sheets D 111 +
D 117)
• Switch off VWZ and vent to atmospheric
pressure
• Open plug (
U
25
) or (
U
26
).
• Drain off cooling liquid:
- VWZ
(14)
➝
drain cock (
K
4
).
- VWZ (13)
➝
drain cock (
K
4
). Drainage is
completed by opening plug (
K
41
) at the base
of the radiator (
R
).
• Disconnect the cables of following devices
at the terminal box (
G
) :
- VWZ
(14)
➝
thermostat (
U
1
) and level switch
(
V
4
).
- VWZ
(13)
➝
thermostat (
U
), level switch (
V
4
)
and fan (
R
1
).
- Disconnection is unnecessary if you have a
cable conduit and open the cover.
• Support the water jacket (
Y
4
) by slings from
a crane.
• Remove the allen bolts (
Y
41
) with an extended
allen key (approx. 1 m).
• Separate the water jacket (
Y
4
) from the con-
nection cover (
Y
5
) with a crane and place on
wooden blocks.
• Refi t the water jacket in the reverse order.
• Use new sealing rings if necessary.
• Fill with coolant at (
H
4
).
2. Changing LP and HP Stages (fi g. 20)
• Removal and Refi tting of LP and HP stages are the same.
2.1
Removal of Stages
• Remove water jacket (see above).
• Drain bearing oil:
- LP Stage at (
K
1
) / HP Stage at (
K
2
).
• Support stage (
S
1
) or (
S
2
) by slings from crane.
• Remove allen bolts (
S
11
) or (
S
21
).
• With gentle rocking movements, withdraw stage from fl ange complete with half coupling.
2.2 Refi tting of Stages
•
Before refi tting, clean out the connecting passage ways (
Y
55
) in the connection cover (
Y
5
).
• When not replacing the stages, the ports (
S
15
fi g. 27) must be cleaned, taking care that no dirt enters the compression cham-
bers (
S
16
fi g. 27).
• Lightly smear both faces of gasket (30) with anti-seize, non-setting universal jointing compound (see E117/1).
• Refi tting is reverse of removal.
• Use new sealing rings if necessary.
• Fill bearing oil tanks:
- LP stage at (
H
1
) / HP stage at (
H
2
).
• Refi t water jacket (see above)
3. Removal and Reassembly of Drive (fi g. 21)
• Disconnect cable of motor (
G
1
).
• Remove hex-nuts (
G
11
) and withdraw motor from mounting
fl ange (
G
2
) with half coupling (
G
3
).
• Remove
hex-nuts
(
G
51
) from mounting fl ange (
G
2
)
and separate from base frame (
G
5
).
• Remove hex-nuts (
G
21
) and with-
draw mounting fl ange (
G
2
)
from gearbox housing
(
Y
3
).
• The half coupling (
G
3
) can
now easily be reached.
• Refi t in reverse order.