10
Maintenance
610.44434.40.000 · 08.2019
38
/
44
© Gardner Denver Deutschland GmbH
Maintenance
Maintenance
For the safe operation of the G-BH1 | G-BH9, the following maintenance intervals
are recommended. They are dependent on the operating conditions and must be
adjusted by the user as necessary.
Maintenance interval
Maintenance measure
To be car-
ried out by
Depending on the
amount of dirt
Exterior
: Check surfaces and attachments for deposits and
clean if necessary (e.g. with compressed air).
Operating
personnel
Interior
: Check any areas that convey material for deposits
and clean or replace if necessary.
Fitter
Annually
Check the control for error messages by disconnecting the
sensors (e.g. bimetal switch, PTC resistor). Remedy the cause
of the error for any malfunctions.
Electrician
20.000 h or
2.5 years
1. Replace the rolling bearing.
2. Replace the radial shaft seal.
Maintenance intervals were established based on reference condi-
tions [
➙
4].
Different ambient and operating conditions increase (e.g. lack of
continuous operation, lower pressure differences) or reduce (e.g.
operation with drive control, rapid accelerations, vibrations, ex-
tended storage periods) the values.
Detailed statements are only possible when taking the actual am-
bient and operating conditions into consideration.
Service*
* Maintenance and repair by qualified personnel is possible when the repair manu-
al is available.
Repairs and complaints
Please consult the service department regarding repairs and complaints before
sending them to the manufacturer.
▪
Gardner Denver Deutschland GmbH
Industriestraße 26
97616 Bad Neustadt
Tel.: +49 9771 6888 2000
Fax: +49 9771 6888 11 2000
E-mail: [email protected]
Internet: www.gd-elmorietschle.com
Ordering spare parts
Spare parts order as per repair manual [
➙
6].