background image

 

 

WARRANTY 

ROTARY SCREW COMPRESSORS AND VACUUM PACKAGES 

OIL INJECTED – OIL FREE 

 

 

 

GENERAL PROVISIONS AND LIMITATIONS

 

Gardner Denver (the “Company”) warrants to each original retail purchaser (“Purchaser”) of its new products from the Company or its authorized 
distributor that such products are, at the time of delivery to the Purchaser, made with good material and workmanship.  No warranty is made with 
respect to: 
 
1. 

Any product which has been repaired or altered in such a way, in the Company’s judgment, as to affect the product adversely. 

 
2. 

Any product which has, in the Company’s judgment been subject to negligence, accident, improper storage, or improper installation or 
application. 

 
3. 

Any product which has not been operated or maintained in accordance with the recommendations of the Company. 

 
4. 

Components or accessories manufactured, warranted and/or serviced by others. 

 
5. 

Any reconditioned or prior owned product. 

 
Claims for items described in (4) above should be submitted directly to the manufacturer. 
 

WARRANTY PERIOD

 

The Company’s obligation under this warranty is limited to repairing or, at its option, replacing, during normal business hours at an authorized service 
facility of the Company, and part which in its judgment proved not to be as warranted within the applicable Warranty Period as follows. 
 

AIRENDS

 

Airends, consisting of all parts within and including the cylinder and gear housing, are warranted for 24 months from date of initial use or 27 months 
from date of shipment to the purchaser, whichever occurs first. 
 
Any disassembly or partial disassembly of the airend, or failure to return the “unopened” airend per Company instructions, will be cause for denial of 
warranty. 
 

MAJOR PACKAGE COMPONENTS

 

Air or water cooled coolers and the AirPilot Controllers are warranted for 24 months from date of initial use or 27 months from date of shipment to the 
first purchaser, whichever occurs first, as provided in, and subject to the terms of the original component manufacturer’s warranty.

 

 
DRIVE AND FAN MOTOR 

The drive and fan motor (if applicable) are warranted for 60 months from start-up or 63 months from shipment, whichever occurs first.  The warranty is 
applicable only to Toshiba low voltage motors (600 Volts or less).  High voltage motors and other manufacturer motors furnished due to customer 
request or special requirements carry the motor manufacturer’s warranty. 
 

OTHER COMPONENTS

 

All other components are warranted for 12 months from date of initial use or 15 months from date of shipment to first purchaser, whichever occurs first. 
 

LABOR TRANSPORTATION AND INSPECTION

 

The Company will provide labor, by Company representative or authorized service personnel, for repair or replacement of any product or part thereof 
which in the Company’s judgment is proved not to be as warranted.  Labor shall be limited to the amount specified in the Company’s labor rate 
schedule. 
 
Labor costs in excess of the Company rate schedule amounts or labor provided by unauthorized service personnel is not provided for by this warranty. 
 
All costs of transportation of product, labor or parts claimed not to be as warranted and, of repaired or replacement parts to or from such service 
facilities shall be borne by the Purchaser.  The Company may require the return of any part claimed not to be as warranted to one of its facilities as 
designated by Company, transportation prepaid by Purchaser, to establish a claim under this warranty. 
 
Replacement parts provided under the terms of the warranty are warranted for the remainder of the Warranty Period of the product upon which 
installed to the same extent as if such parts were original components. 
 

DISCLAIMER

 

THE FOREGOING WARRANTY IS EXCLUSIVE AND IT IS EXPRESSLY AGREED THAT, EXCEPT AS TO TITLE, THE COMPANY MAKES NO 
OTHER WARRANTIES AND HEREBY EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION, EXPRESSED, 
IMPLIED OR STATUTORY WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
USE. 
 
THE REMEDY PROVIDED UNDER THIS WARRANTY SHALL BE THE SOLE, EXCLUSIVE AND ONLY REMEDY AVAILABLE TO PURCHASER 
AND IN NO CASE SHALL THE COMPANY BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES.  UNDER NO CIRCUMSTANCES 
SHALL THE COMPANY BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, EXPENSES, LOSSES OR 
DELAYS HOWSOEVER CAUSED. 
 
NO STATEMENT, REPRESENTATION, AGREEMENT, OR UNDERSTANDING, ORAL OR WRITTEN, MADE BY ANY AGENT, DISTRIBUTOR, 
REPRESENTATIVE, OR EMPLOYEE OF THE COMPANY WHICH IS NOT CONTAINED IN THIS WARRANTY WILL BE BINDING UPON THE 
COMPANY UNLESS MADE IN WRITING AND EXECUTED BY AN OFFICER OF THE COMPANY. 
 
THIS WARRANTY SHALL NOT BE EFFECTIVE AS TO ANY CLAIM WHICH IS NOT PRESENTED WITHIN 30 DAYS AFTER THE DATE UPON 
WHICH THE PRODUCT IS CLAIMED NOT TO HAVE BEEN AS WARRANTED.  ANY ACTION FOR BREACH OF THIS WARRANTY MUST BE 
COMMENCED WITHIN ONE YEAR AFTER THE DATE UPON WHICH THE CAUSE OF ACTION OCCURRED. 
 
ANY ADJUSTMENT MADE PURSUANT TO THIS WARRANTY SHALL NOT BE CONSTRUED AS AN ADMISSION BY THE COMPANY THAT 
ANY PRODUCT WAS NOT AS WARRANTED.

 

 

BN-07  R 10/04 

COPYRIGHT

©

 2004 Gardner Denver, Inc. 

Содержание CHAMPION ROTORCHAMP EFB99B

Страница 1: ...CHAMPION 13 8 620 Version 10 May 2 2006 ROTORCHAMP BASE MOUNTED COMPRESSORS MODELS EFB99B EFB99G 7 5 10 15 HP OPERATING AND SERVICE MANUAL...

Страница 2: ...rt maintenance and repair services For the location of your local authorized Champion Air Compressor distributor refer to the yellow pages of your phone directory or contact Factory Champion 1301 N Eu...

Страница 3: ...presence of a hazard which will cause severe personal injury death or substantial property damage if the warning is ignored WARNING Warning is used to indicate the presence of a hazard which can caus...

Страница 4: ...ed Airends i Foreword ii Index iv List Of Illustrations vi Section 1 General Information 1 Section 2 Installation 7 Section 3 Starting Operating Procedures 14 Section 4 Controls Instrumentation 17 Sec...

Страница 5: ...pgrade Procedure 27 Lubrication Motor 12 Lubrication Oil Cooler Oil Filter Separator 24 Section 5 24 Lubrication Cooling And Sealing 1 Maintenance Schedule Section 8 38 Minimum Pressure Check Valve 18...

Страница 6: ...22 Sheave Alignment 36 Sheave And Shaft Seal Replacing 36 Solenoid Valve 18 Starter Control Box 19 Hourmeter 19 Starting Operating Procedures Section 3 14 Starting The Unit 15 Unit Cold 15 Unit Hot 1...

Страница 7: ...rol Schematic 18 Figure 4 2 Maximum Setpoint For Nema 4 Pressure Switch 21 Figure 4 3 Wiring Diagram 23 Figure 5 1 Approximate Oil System Capacities 25 Figure 5 2 Oil Change Interval 26 Figure 5 3 Oil...

Страница 8: ...B As meshing continues more of the main rotor lobe enters the secondary rotor grove normal volume is reduced and pressure increases Oil is injected into the cylinder to remove the heat of compression...

Страница 9: ...13 8 620 Page 2 13 8 620 Page 2 300EFB797 A Ref Drawing Figure 1 2 COMPRESSOR ILLUSTRATION...

Страница 10: ...ing not suitable for human consumption Do not loosen or remove the oil filler plug drain plugs covers the thermostatic mixing valve or break any connections etc in the compressor air or oil system unt...

Страница 11: ...d tagout before working on the unit this machine is automatically controlled and may start at any time An Excess Flow Valve should be on all compressed air supply hoses exceeding 1 2 inch inside diame...

Страница 12: ...13 8 620 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...

Страница 13: ...13 8 620 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...

Страница 14: ...hould be installed where it is protected from rain snow and freezing temperatures in a clean well lighted well ventilated area with ample space all around for maintenance Select a location that provid...

Страница 15: ...possible install the unit near level Temporary installation may be made at a maximum 5 angle lengthwise or 5 sidewise Mounting bolts are not normally required However installation conditions such as...

Страница 16: ...Service panels are provided for maintenance access Be sure to allow enough space around the unit for the doors to be removed Any of the enclosure panels may be removed by opening the latch and liftin...

Страница 17: ...ations should be avoided where possible Installation next to a heated building where enough heat can be used to keep the compressor room above freezing will save many complications in the operation an...

Страница 18: ...lded together an air receiver must be located between the two units DANGER Discharge air used for breathing will cause severe injury or death Consult filtration specialists for additional filtration a...

Страница 19: ...asing intervals for ball bearing motors For additional information refer to the motor manufacturer s instructions The following procedure should be used in regreasing 1 Stop the unit 2 Disconnect lock...

Страница 20: ...GREASING INTERVAL Type of Service Typical Rating Relubrication Interval Up to 150 HP 112 KW 18 Months Standard One or Two Shift Operation Above 150 HP 112 KW 12 Months Up to 150 HP 112 KW 9 Months Sev...

Страница 21: ...ain intervals of RotorLub 4000 lubricant Use only genuine Champion filters designed and specified for this compressor DANGER Always stop the unit and release air pressure before removing oil filler pl...

Страница 22: ...r doors Check all screws and latches for tightness Be sure doors are closed and latched STARTING THE UNIT Observe the following starting procedures Unit Cold 1 Open the air service valve customer furn...

Страница 23: ...Refer to Maintenance Schedule SECTION 8 page 38 STOPPING THE UNIT 1 To stop compressor operation place the switch in the OFF position The oil reservoir will automatically blow down as the motor stops...

Страница 24: ...ere is no demand the motor stops after a time delay is completed The compressor drive motor and wiring are protected from overload by a thermal overload relay inside of the control box The control sys...

Страница 25: ...he operating conditions Solenoid Valve Figure 4 1 The solenoid valve is operated by the controller When energized the valve closes the inlet valve opens and the package starts compressing air When the...

Страница 26: ...control components are located on the combination starter control box Hourmeter A continuous reading nonreset type hourmeter displays the accumulated operating time of the unit and provides a conveni...

Страница 27: ...rator temperature fault indicator 3 Yellow High low temperature warning 4 Green Automatic mode indicator 5 Green Power on indicator CAUTION Machine damage will occur if compressor is repeatedly restar...

Страница 28: ...SYSTEM PRESSURE PSI LOAD UNLOAD 100 85 100 125 110 125 150 135 150 175 160 175 Figure 4 2 MAXIMUM SETPOINT FOR NEMA 4 PRESSURE SWITCH WARNING Electrical shock can cause injury or death Open main disc...

Страница 29: ...jumper on the pair of pins furthest from the edge of the controller The shutdown will occur prior to the compressor reaching its normal operating temperature Disconnect power remove the jumper and cl...

Страница 30: ...13 8 620 Page 23 Figure 4 3 WIRING DIAGRAM 300EFB542 D Ref Drawing...

Страница 31: ...e High Temperature Operation this section or low temperature see Installation for Cold Weather Section 2 page 10 RotorLub 4000 Lubricating Coolant is a superior petroleum base lubricant formulated and...

Страница 32: ...a careless manner 7 1 2 to 15 HP 5 6 to 11 2 KW Refill Capacity For Normal Oil Change 1 0 U S Gallon 3 8 Liters Bottom of Site Glass to Top of Site Glass 1 0 U S Quart 9 Liter Figure 5 1 APPROXIMATE O...

Страница 33: ...oil is hot will help to prevent varnish deposits and carry away impurities To drain the system use one of the following methods 1 Be sure the unit is completely off and that no air pressure is in the...

Страница 34: ...arryover and should be investigated Use only CLEAN containers and funnels so no dirt enters the reservoir Provide for clean storage of oils Changing the oil will be of little benefit if done in a care...

Страница 35: ...of all pressure disconnect lockout and tagout power supply to the starter before removing valves caps plugs fittings bolts and filters WARNING High temperature operation can cause damage to equipment...

Страница 36: ...m which is detrimental to compressor lubrication and could cause oil carryover If moisture is observed in the oil reservoir drain the moisture and correct the condition causing the accumulation See Co...

Страница 37: ...lement 3 Clean the gasket face of the filter body 4 Coat the new element gasket with clean lubricant used in the unit 5 Screw new element on filter body and tighten by hand DO NOT OVERTIGHTEN ELEMENT...

Страница 38: ...sor cylinder Oil carry over through the service lines may be caused by a faulty oil separator overfilling of the oil reservoir oil that foams oil return line malfunction or water condensate in the oil...

Страница 39: ...r 2 Disconnect lockout and tagout the power supply to the starter 3 Remove the minimum pressure check valve air oil separator housing cover 4 Lift out the air oil separator element 5 Inspect and or re...

Страница 40: ...e oil filter outlet and check with a thermometer Oil Inlet Pressure Check at the fitting in the line near the compressor oil inlet With air receiver pressure at 100 psi 6 9 bar oil inlet pressure shou...

Страница 41: ...with air nozzle Direct air blast parallel to element pleats at a slight upward angle Do not point air blast directly at element 3 Inspect for rupture by placing a bright light inside the element The s...

Страница 42: ...nsion the belts as shown in Figure 7 2 Page 37 REPLACING THE COMPRESSOR BELTS 1 Disconnect lockout and tagout the power supply to the starter 2 Remove the belt guards 3 Using adjusting screws jack the...

Страница 43: ...e motor which is supported between 2 posts and a slotted platform for the Tempest units To achieve proper sheave alignment the sheaves must be adjusted for both parallel and angular alignment The alig...

Страница 44: ...eplaced It s important to note that the belts should not be over tightened To check belt tension use a Gardner Denver Belt Tension Gauge Part Number 00543217 V belt tension will drop after the first 8...

Страница 45: ...equired clean the exterior fin surfaces of the cores by blowing compressed air carrying a nonflammable safety solvent in a direction opposite that of the cooling fan air flow This cleaning operation w...

Страница 46: ...ck Reservoir Oil Level Check for Proper Load Unload Check Fault Indicator Lights Check Dirt Accumulation on Cooler Change Oil Filter Element Clean Oil Return Strainer Change Compressor Lubricant Rotor...

Страница 47: ...tinue to blow 4 Motor starter overload heaters trip 4 Reset and investigate cause of overload Compressor does not unload or load 1 Improperly adjusted control 1 Refer to SECTION 4 page 17 and adjust c...

Страница 48: ...oil return lines 2 Tighten or replace faulty lines 3 Ruptured oil separator element 3 Replace element 4 Loose assembly 4 Tighten all fittings and gaskets 5 Foam caused by use of incorrect oil 5 Use Ch...

Страница 49: ...imply indicates the operating state of the controller When it is off the compressor operation is stopped If the switch is in the OFF position switch it to ON to start the compressor If the light is of...

Страница 50: ...high voltage Disconnect power Refer to the transformer connection information in the installation instructions and connect the transformer properly Check that the motor is properly connected for the a...

Страница 51: ...store power If overload problems persist contact a qualified electrician or motor shop Measure all incoming voltages with the motor off and at full load Measure amps while running full load Correct wi...

Страница 52: ...initial use or 15 months from date of shipment to first purchaser whichever occurs first LABOR TRANSPORTATION AND INSPECTION The Company will provide labor by Company representative or authorized serv...

Страница 53: ...orth Euclid Avenue Princeton Illinois 63156 USA Phone 815 875 3321 Fax 815 872 0421 E mail champion championpneumatic com Plants in Princeton IL and Manteca CA Due to Champion s continuing product dev...