13-8-620    Page 11 

 

INLET LINE LENGTHS 

 

 

Length of Inlet Line 

Diameter of Pipe Size 

0 to 10 Feet ............................................. Same as Compressor Inlet Opening 
10 to 17 Feet ........................................... One Size Larger Than Inlet Opening 
17 to 38 Feet ........................................... Two Sizes Larger Than Inlet Opening 

 
 

DISCHARGE SERVICE LINE

 - The discharge service line connection is made at the right hand corner of 

the package when viewed from the control box end, viewed from the oil cooler side.  A hand operated 
valve, (air service valve) must be installed between the unit and the customer’s air system.  If a fast 
operating valve such as a ball valve is used, it must be closed slowly to give the intake valve time to shut 
and keep the discharge pressure from spiking.  When manifolding two or more rotary screw units on the 
same line, each unit is isolated by the check valve in the unit discharge line.  If a rotary screw unit is 
manifolded to another compressor, be sure the other compressor has a check valve in the line between 
the machine and the manifold.  If a rotary screw and a reciprocating compressor are manifolded together, 
an air receiver must be located between the two units. 
 
 

DANGER 

Discharge air used for breathing will cause severe injury or death. 

 

Consult filtration specialists for additional filtration and treatment equipment to 
meet health and safety standards. 

 

 

ELECTRICAL WIRING

 - All of the electrical connections and controls are factory wired for the voltage 

specified on the order.  Verify that the available voltage source matches that shown on the compressor 
package nameplate before installing the compressor package.  It is necessary only to connect the 
package to the supply and ground of the branch circuit.  The connections to the compressor package are 
made with the electrical controls box, accessible by opening the cover of the box. 
 
The 24CA4820 Control Transformer (Cutler-Hammer C0250G6U) is connectable for a variety of input 
voltages.  Ensure that it is properly connected prior to applying power to the package.  Recommended 
connections are: 
 
 

Line Voltage 

Primary Connect 

Secondary Connect 

200-208 

H1 & H2 

X1 & X4 

230-240 

H1 & H2 

X1 & X3 

380-416 

H1 & H3 

X1 & X3 

460-480 

H1 & H4 

X1 & X3 

575-600 

H1 & H5 

X1 & X3 

 
 

WARNING 

Electrical shock can cause injury or death.  Open main disconnect switch, 
lockout and tagout before working on control box. 

 

 

Содержание CHAMPION ROTORCHAMP EFB99B

Страница 1: ...CHAMPION 13 8 620 Version 10 May 2 2006 ROTORCHAMP BASE MOUNTED COMPRESSORS MODELS EFB99B EFB99G 7 5 10 15 HP OPERATING AND SERVICE MANUAL...

Страница 2: ...rt maintenance and repair services For the location of your local authorized Champion Air Compressor distributor refer to the yellow pages of your phone directory or contact Factory Champion 1301 N Eu...

Страница 3: ...presence of a hazard which will cause severe personal injury death or substantial property damage if the warning is ignored WARNING Warning is used to indicate the presence of a hazard which can caus...

Страница 4: ...ed Airends i Foreword ii Index iv List Of Illustrations vi Section 1 General Information 1 Section 2 Installation 7 Section 3 Starting Operating Procedures 14 Section 4 Controls Instrumentation 17 Sec...

Страница 5: ...pgrade Procedure 27 Lubrication Motor 12 Lubrication Oil Cooler Oil Filter Separator 24 Section 5 24 Lubrication Cooling And Sealing 1 Maintenance Schedule Section 8 38 Minimum Pressure Check Valve 18...

Страница 6: ...22 Sheave Alignment 36 Sheave And Shaft Seal Replacing 36 Solenoid Valve 18 Starter Control Box 19 Hourmeter 19 Starting Operating Procedures Section 3 14 Starting The Unit 15 Unit Cold 15 Unit Hot 1...

Страница 7: ...rol Schematic 18 Figure 4 2 Maximum Setpoint For Nema 4 Pressure Switch 21 Figure 4 3 Wiring Diagram 23 Figure 5 1 Approximate Oil System Capacities 25 Figure 5 2 Oil Change Interval 26 Figure 5 3 Oil...

Страница 8: ...B As meshing continues more of the main rotor lobe enters the secondary rotor grove normal volume is reduced and pressure increases Oil is injected into the cylinder to remove the heat of compression...

Страница 9: ...13 8 620 Page 2 13 8 620 Page 2 300EFB797 A Ref Drawing Figure 1 2 COMPRESSOR ILLUSTRATION...

Страница 10: ...ing not suitable for human consumption Do not loosen or remove the oil filler plug drain plugs covers the thermostatic mixing valve or break any connections etc in the compressor air or oil system unt...

Страница 11: ...d tagout before working on the unit this machine is automatically controlled and may start at any time An Excess Flow Valve should be on all compressed air supply hoses exceeding 1 2 inch inside diame...

Страница 12: ...13 8 620 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...

Страница 13: ...13 8 620 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...

Страница 14: ...hould be installed where it is protected from rain snow and freezing temperatures in a clean well lighted well ventilated area with ample space all around for maintenance Select a location that provid...

Страница 15: ...possible install the unit near level Temporary installation may be made at a maximum 5 angle lengthwise or 5 sidewise Mounting bolts are not normally required However installation conditions such as...

Страница 16: ...Service panels are provided for maintenance access Be sure to allow enough space around the unit for the doors to be removed Any of the enclosure panels may be removed by opening the latch and liftin...

Страница 17: ...ations should be avoided where possible Installation next to a heated building where enough heat can be used to keep the compressor room above freezing will save many complications in the operation an...

Страница 18: ...lded together an air receiver must be located between the two units DANGER Discharge air used for breathing will cause severe injury or death Consult filtration specialists for additional filtration a...

Страница 19: ...asing intervals for ball bearing motors For additional information refer to the motor manufacturer s instructions The following procedure should be used in regreasing 1 Stop the unit 2 Disconnect lock...

Страница 20: ...GREASING INTERVAL Type of Service Typical Rating Relubrication Interval Up to 150 HP 112 KW 18 Months Standard One or Two Shift Operation Above 150 HP 112 KW 12 Months Up to 150 HP 112 KW 9 Months Sev...

Страница 21: ...ain intervals of RotorLub 4000 lubricant Use only genuine Champion filters designed and specified for this compressor DANGER Always stop the unit and release air pressure before removing oil filler pl...

Страница 22: ...r doors Check all screws and latches for tightness Be sure doors are closed and latched STARTING THE UNIT Observe the following starting procedures Unit Cold 1 Open the air service valve customer furn...

Страница 23: ...Refer to Maintenance Schedule SECTION 8 page 38 STOPPING THE UNIT 1 To stop compressor operation place the switch in the OFF position The oil reservoir will automatically blow down as the motor stops...

Страница 24: ...ere is no demand the motor stops after a time delay is completed The compressor drive motor and wiring are protected from overload by a thermal overload relay inside of the control box The control sys...

Страница 25: ...he operating conditions Solenoid Valve Figure 4 1 The solenoid valve is operated by the controller When energized the valve closes the inlet valve opens and the package starts compressing air When the...

Страница 26: ...control components are located on the combination starter control box Hourmeter A continuous reading nonreset type hourmeter displays the accumulated operating time of the unit and provides a conveni...

Страница 27: ...rator temperature fault indicator 3 Yellow High low temperature warning 4 Green Automatic mode indicator 5 Green Power on indicator CAUTION Machine damage will occur if compressor is repeatedly restar...

Страница 28: ...SYSTEM PRESSURE PSI LOAD UNLOAD 100 85 100 125 110 125 150 135 150 175 160 175 Figure 4 2 MAXIMUM SETPOINT FOR NEMA 4 PRESSURE SWITCH WARNING Electrical shock can cause injury or death Open main disc...

Страница 29: ...jumper on the pair of pins furthest from the edge of the controller The shutdown will occur prior to the compressor reaching its normal operating temperature Disconnect power remove the jumper and cl...

Страница 30: ...13 8 620 Page 23 Figure 4 3 WIRING DIAGRAM 300EFB542 D Ref Drawing...

Страница 31: ...e High Temperature Operation this section or low temperature see Installation for Cold Weather Section 2 page 10 RotorLub 4000 Lubricating Coolant is a superior petroleum base lubricant formulated and...

Страница 32: ...a careless manner 7 1 2 to 15 HP 5 6 to 11 2 KW Refill Capacity For Normal Oil Change 1 0 U S Gallon 3 8 Liters Bottom of Site Glass to Top of Site Glass 1 0 U S Quart 9 Liter Figure 5 1 APPROXIMATE O...

Страница 33: ...oil is hot will help to prevent varnish deposits and carry away impurities To drain the system use one of the following methods 1 Be sure the unit is completely off and that no air pressure is in the...

Страница 34: ...arryover and should be investigated Use only CLEAN containers and funnels so no dirt enters the reservoir Provide for clean storage of oils Changing the oil will be of little benefit if done in a care...

Страница 35: ...of all pressure disconnect lockout and tagout power supply to the starter before removing valves caps plugs fittings bolts and filters WARNING High temperature operation can cause damage to equipment...

Страница 36: ...m which is detrimental to compressor lubrication and could cause oil carryover If moisture is observed in the oil reservoir drain the moisture and correct the condition causing the accumulation See Co...

Страница 37: ...lement 3 Clean the gasket face of the filter body 4 Coat the new element gasket with clean lubricant used in the unit 5 Screw new element on filter body and tighten by hand DO NOT OVERTIGHTEN ELEMENT...

Страница 38: ...sor cylinder Oil carry over through the service lines may be caused by a faulty oil separator overfilling of the oil reservoir oil that foams oil return line malfunction or water condensate in the oil...

Страница 39: ...r 2 Disconnect lockout and tagout the power supply to the starter 3 Remove the minimum pressure check valve air oil separator housing cover 4 Lift out the air oil separator element 5 Inspect and or re...

Страница 40: ...e oil filter outlet and check with a thermometer Oil Inlet Pressure Check at the fitting in the line near the compressor oil inlet With air receiver pressure at 100 psi 6 9 bar oil inlet pressure shou...

Страница 41: ...with air nozzle Direct air blast parallel to element pleats at a slight upward angle Do not point air blast directly at element 3 Inspect for rupture by placing a bright light inside the element The s...

Страница 42: ...nsion the belts as shown in Figure 7 2 Page 37 REPLACING THE COMPRESSOR BELTS 1 Disconnect lockout and tagout the power supply to the starter 2 Remove the belt guards 3 Using adjusting screws jack the...

Страница 43: ...e motor which is supported between 2 posts and a slotted platform for the Tempest units To achieve proper sheave alignment the sheaves must be adjusted for both parallel and angular alignment The alig...

Страница 44: ...eplaced It s important to note that the belts should not be over tightened To check belt tension use a Gardner Denver Belt Tension Gauge Part Number 00543217 V belt tension will drop after the first 8...

Страница 45: ...equired clean the exterior fin surfaces of the cores by blowing compressed air carrying a nonflammable safety solvent in a direction opposite that of the cooling fan air flow This cleaning operation w...

Страница 46: ...ck Reservoir Oil Level Check for Proper Load Unload Check Fault Indicator Lights Check Dirt Accumulation on Cooler Change Oil Filter Element Clean Oil Return Strainer Change Compressor Lubricant Rotor...

Страница 47: ...tinue to blow 4 Motor starter overload heaters trip 4 Reset and investigate cause of overload Compressor does not unload or load 1 Improperly adjusted control 1 Refer to SECTION 4 page 17 and adjust c...

Страница 48: ...oil return lines 2 Tighten or replace faulty lines 3 Ruptured oil separator element 3 Replace element 4 Loose assembly 4 Tighten all fittings and gaskets 5 Foam caused by use of incorrect oil 5 Use Ch...

Страница 49: ...imply indicates the operating state of the controller When it is off the compressor operation is stopped If the switch is in the OFF position switch it to ON to start the compressor If the light is of...

Страница 50: ...high voltage Disconnect power Refer to the transformer connection information in the installation instructions and connect the transformer properly Check that the motor is properly connected for the a...

Страница 51: ...store power If overload problems persist contact a qualified electrician or motor shop Measure all incoming voltages with the motor off and at full load Measure amps while running full load Correct wi...

Страница 52: ...initial use or 15 months from date of shipment to first purchaser whichever occurs first LABOR TRANSPORTATION AND INSPECTION The Company will provide labor by Company representative or authorized serv...

Страница 53: ...orth Euclid Avenue Princeton Illinois 63156 USA Phone 815 875 3321 Fax 815 872 0421 E mail champion championpneumatic com Plants in Princeton IL and Manteca CA Due to Champion s continuing product dev...

Отзывы: