13-8-620 Page 8
WARNING
For aluminum oil coolers, do not use any cleaning solution that is not
compatible with aluminum. Use of improper solution may result in damage to
the cooler.
Figure 2-1 – TYPICAL COMPRESSOR ROOM
Minimum Air Flow* For Compressor
And Cooling (cubic Feet/Minute)
Air
Cooled
All Models
3000 cfm
* 80
°
F Inlet Air
Figure 2-2 – AIR FLOW CHART
FOUNDATION
- The rotary screw compressor requires no special foundation, but should be mounted on
a smooth, solid surface. Whenever possible install the unit near level. Temporary installation may be
made at a maximum 5
°
angle lengthwise or 5
°
sidewise. Mounting bolts are not normally required.
However, installation conditions such as piping rigidity, angle of tilt, or danger of shifting from outside
vibration or moving vehicles may require the use of mounting bolts and shims to provide uniform support
for the base. Belt alignment and tension should be checked after installation. (For information on belt
alignment and tension, see SECTION 7, page 35.
OIL RESERVOIR DRAIN
- The oil drain is piped from the bottom of the reservoir to the side of the frame.
This drain is approximately 20 inches above the floor level.
Содержание CHAMPION ROTORCHAMP EFB99B
Страница 9: ...13 8 620 Page 2 13 8 620 Page 2 300EFB797 A Ref Drawing Figure 1 2 COMPRESSOR ILLUSTRATION...
Страница 12: ...13 8 620 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 13: ...13 8 620 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 30: ...13 8 620 Page 23 Figure 4 3 WIRING DIAGRAM 300EFB542 D Ref Drawing...