manualshive.com logo in svg
background image

Basic Safety Instructions 

112037 

Basic Safety Instructions 

2.1 

General information 

WARNING ! 

Warning notices must be observed. Disregarding them may lead to damage to health 
and property. 

The 

biovac 106 Aspiration Systems

 must be operated by personnel who can detect im-

pending dangers and take action to prevent them from materialising.  
The manufacturer or authorized workshops will only service or maintain the aspiration sys-
tems if it is accompanied by a fully completed damage report. Precise information about the 
contamination (also negative information if necessary) and thorough cleaning of the system 
are legally binding parts of the contract.  
Contaminated aspiration systems and their individual parts must be disposed of in accor-
dance with the legal regulations.  
The local regulations apply in foreign countries. 

2.2 

Electricity 

The 

biovac 106 Aspiration Systems

 are supplied for operating mode S1. Please note that 

the testing must be repeated in accordance with DIN EN 0105, DIN EN 0702 and BGV A2 in 
case of portable devices.  
The local regulations apply in foreign countries. 

Please note the following when connecting to the electrical power supply system: 

The electrical power supply system must have a protective connector according to DIN 
VDE 0100-410 (IEC 60364-4-41). 

The protective connector must not have any breaks. 

The connecting cable must not be damaged. 

2.3 

Mechanical System 

Improper use can lead to injuries or material damage. Observe the following instructions: 

Only operate the biovac aspiration systems with hoses of the specified dimensions.  

Solid particles in the pumping medium impair the pumping action and can lead to dam-
age. Prevent their penetrating into the pump.  

Hazardous substances must be separated out as far as this is technically possible before 
they reach the pump.  

External mechanical stresses and vibrations must not be transmitted to the system. Only 
use a flexible laboratory hose for connecting the aspiration system.  

The overpressure generated at the pressure port must not exceed 1 bar. 

The pump must not be used to pump liquids.  

Set the biovac aspiration systems on a flat and horizontal surface. 

Do not close the space beyond the bottom of the device in order to enable the pump to 
cool. 

Содержание biovac 106 with 2 L Container

Страница 1: ...Operation Manual EN Translation of the german original manual Aspiration Systems Models biovac 106 with 2 L Container biovac 106 with 4 L Container 112037 2017 04 10...

Страница 2: ...ritten permission of Co Gardner Denver Thomas GmbH All rights under the copyright laws are expressly reserved by Co Gardner Denver Thomas GmbH We reserve the right to make changes and amendments Gardn...

Страница 3: ...eration 14 5 4 Storage 15 5 5 Scrap Disposal 15 6 Maintenance and Servicing 16 6 1 General Requirements 16 6 2 Maintenance Performed by the User 16 6 2 1 Maintenance of the aspiration systems 16 6 2 1...

Страница 4: ...s must have the technical competence required to perform the work that has to be done The user must authorize the operating personnel to do the work that has to be done The personnel must have read an...

Страница 5: ...ring method grade 2 DIN EN 60204 1 2014 10 Safety of machinery Electrical equipment of machines Part 1 General requirements DIN EN 61000 6 2 2011 06 DIN EN 61000 6 4 2011 09 Electromagnetic compatibil...

Страница 6: ...se of portable devices The local regulations apply in foreign countries Please note the following when connecting to the electrical power supply system The electrical power supply system must have a p...

Страница 7: ...ent such sub stances from leaking out of the appliance or pump Treat these substances according to the applicable environmental protection regulations The diaphragm pump control valves and hose lines...

Страница 8: ...a Aspiration System biovac 106 with secretion glass container 2 liters A quick coupling 4 is used for the connection to the diaphragm pump 2 It is provided with a stop valve The used resistant diaphra...

Страница 9: ...hragm pump is used for the safe and precise aspiration of non flammable chemical and biological liquids The fluids can be removed easily and very precisely from slides Petri dishes cell culture contai...

Страница 10: ...Application The biovac 106 Aspiration Systems are intended for the safe and precise extraction and catching of liquid and non explosive excess fluids use in the chemical biological and medical areas g...

Страница 11: ...Technical Data 112037 11 4 Technical Data 4 1 Dimensions Fig 2 Dimension biovac 106 with secretion glass container 2 liters Fig 3 Dimension biovac 106 with secretion PP container 4 liters...

Страница 12: ...mode S 1 Type of protection DIN EN 60529 IP 40 Class of insulation DIN EN 600034 1 F 160 C Dimensions W D H without hose mm 342 363 197 395 363 197 Weight kg 8 0 Order number biovac 106 inclusive mai...

Страница 13: ...vice must be returned in packaging that is suitable for protecting it during transport 5 2 Installation and Connection Procedure Fig 5 Rear side connections biovac 106 with secretion glass container 2...

Страница 14: ...ing plug g Elbow plug with valve d Separator h Connecting coupling of the pump e Float valve b Coupling f PTFE Filter 1 m 2 Liters container i Diaphragm pump Inline filter 0 22 m 4 Liters container hy...

Страница 15: ...rve the operating instructions included when using the handvac 5 4 Storage The pumps are to be stored in a low dust interior room within the temperature range from 5 to 40 C and at a relative air humi...

Страница 16: ...only be performed by the manufacturer or a dealer authorized by him Beware of the pump parts being possibly contaminated by hazardous substances Wear protective clothing if there is contamination The...

Страница 17: ...r no 826801 4 Cross head screwdriver size 2 Order no 826801 2 Open spanner size SW 14 6 2 2 1 Disassembly 1 Disconnect the power supply and ensure that it cannot be switched on again 2 To open the cov...

Страница 18: ...ping ring screw fittings 9 Close the casing by shutting the cover 6 2 2 3 Test Connect the pump to the electrical supply Connect a vacuum measuring device to the suction connector and measure the ulti...

Страница 19: ...only be performed by the manufacturer or authorized workshops CAUTION The user shall be liable for the consequences of an incorrect damage report or a contaminated pump The statements in the damage r...

Страница 20: ...dentify and seal the leak replace the seals and or hoses if necessary Vacuum pump leaking Check the hose connections between the pump heads replace the hoses and or fittings if necessary Pump head lea...

Страница 21: ...ON We are not liable for any damage caused by the installation of any parts not supplied by the manufacturer 8 1 Service kit Diaphragm pump Designation Order no Service kit 402045 The service kit cons...

Страница 22: ...112573 Secretion glass container complete 2 Liters consisting of position 2 6 1 112523 1 2 Secretion glass container 2 Liters 1 828840 3 Cover complete for secretion glass container 1 828840 1 4 Sili...

Страница 23: ...P container complete 4 liters consisting of position 2 7 1 112523 7 2 Secretion PP container with cover 4 liters 1 828853 3 Float valve in the cover 1 112581 4 Silicone hose inside 6 mm x wall thickne...

Страница 24: ...Spare Parts Overview 24 112037 8 2 3 Spare parts view Basic unit complete Fig 10 Explosion view Basic unit complete...

Страница 25: ...PVDF 8 1 8 1 829919 829919 46 Quick release coupling PP NW 7 2 mm 6 4 mm 1 829996 2 829996 2 47 Angle with hose connector PP NW 7 2 mm 6 4 mm 1 829996 1 829996 1 48 Vacuum hose PTFE 8 6x1 mm 0 1 m 828...

Страница 26: ...ospheres part 1 Basic method and requirements Appareils non lectriques destin s tre utilis s en atmosph res explosibles partie 1 prescriptions et m thodologie DIN EN 13463 5 2011 10 Nicht elektrische...

Отзывы: