HEAT EXCHANGERS (OIL/AIR
)
OIL/AIR HEAT EXCHANGERS –
The heat of compression absorbed by the oil injected into the
compressors (for cooling and lubrication) is ultimately rejected in a convenient medium such as air - for
these air-cooled cores. Proper operation of the heat exchangers is essential for the following processes:
·
The oil core delivers a stable, cool (typically 131
°
F at 80
°
F ambient) supply of injection oil to the
compressor. Under these conditions, the oil core allows 15 gpm (56.8 lpm) oil flow with 16 psi
pressure loss at 110 psig discharge pressure. The standard (AEON4000) lubricating and cooling oil
must be kept at a normal operating temperature below 225
°
F in order to preserve its longevity.
·
The air core discharges 144 acfm of compressed air with 110psig of pressure and at a temperature
17
°
F above the ambient level at full load - 30hp package. Be aware that this temperature differential
(aka approach) may increase several degrees due to environmental conditions such as high ambient
temperatures and high ambient humidity.
VENTILATION CONFIGURATION
– Air-cooled cores (radiator-type) are provided as standard feature.
One (1) axial fan, located behind the fresh air inlet grille, delivers an air stream to meet the cooling
demands of the air/oil combination heat exchanger on its way out the package confines. The fan is driven
by a close-coupled, IP54-protected, electric motor which includes its own overload protection. In addition,
an open-weave, non-metallic mesh media is held in place over the fresh air inlet grill to pre clean the
cooling air stream.
Refer to Figure 6-1 for estimates of ventilation requirements. Please note that the air-cooled package
requires the combined total of the heat exchanger plus the enclosure ventilation flow rates (which include
motor ventilation and compressor intake). Furthermore, when package location makes it necessary to
duct fresh cooling air in/out, these ducts must be sized with a maximum (total) pressure loss of .1 inch
water gauge to avoid impacting the heat exchanger cooling air system. An external ventilation fan may
be required to properly evacuate hot air from the compressor room.
Minimum Cooling Air Flow Requirements
Model HP size
CFM
25-30 HP
2684
18-22 kW
3022
FIGURE 6- 1 – Air Flow Chart
HEAT EXCHANGER MAINTENANCE -
All the required hardware, mechanical and electrical connections
have been made at the Gardner Denver factory, thus the only regular maintenance required is to keep the
exterior core fins free from dirt and other airborne debris per the following procedure:
Содержание APEX25-30A
Страница 11: ...13 25 608 Page 10 Figure 1 2 COMPRESSOR ILLUSTRATION VARIABLE SPEED 304USC797 A Ref Drawing...
Страница 12: ...13 25 608 Page 11 Figure 1 3 COMPRESSOR ILLUSTRATION FIXED SPEED 305USC797 A Ref Drawing...
Страница 13: ...13 25 608 Page 12 Figure 1 4 COMPRESSOR ILLUSTRATION TOTAL SYSTEM 301USC804 A Ref Drawing Page 1 of 1...
Страница 27: ...13 25 608 Page 26 Figure 4 2 WIRING DIAGRAM VS 230 VOLT 306USC546 01 Ref Drawing Page 1 of 4...
Страница 28: ...13 25 608 Page 27 Figure 4 3 WIRING DIAGRAM VS 230 VOLT 306USC546 01 Ref Drawing Page 2 of 4...
Страница 29: ...13 25 608 Page 28 Figure 4 3 WIRING DIAGRAM VS 230 VOLT 306USC546 01 Ref Drawing Page 3 of 4...
Страница 30: ...13 25 608 Page 29 Figure 4 3 WIRING DIAGRAM VS 230 VOLT 306USC546 01 Ref Drawing Page 4 of 4...
Страница 31: ...13 25 608 Page 30 Figure 4 3 WIRING DIAGRAM VS 575 VOLT 307USC546 02 Ref Drawing Page 1 of 4...
Страница 32: ...13 25 608 Page 31 Figure 4 4 WIRING DIAGRAM VS 575 VOLT 307USC546 02 Ref Drawing Page 2 of 4...
Страница 33: ...13 25 608 Page 32 Figure 4 4 WIRING DIAGRAM VS 575 VOLT 307USC546 02 Ref Drawing Page 3 of 4...
Страница 34: ...13 25 608 Page 33 Figure 4 4 WIRING DIAGRAM VS 575 VOLT 307USC546 02 Ref Drawing Page 4 of 4...
Страница 35: ...13 25 608 Page 34 Figure 4 4 WIRING DIAGRAM VS 380 460 VOLT 311USC546 01 Ref Drawing Page 1 of 4...
Страница 36: ...13 25 608 Page 35 Figure 4 5 WIRING DIAGRAM VS 380 460 VOLT 311USC546 01 Ref Drawing Page 2 of 4...
Страница 37: ...13 25 608 Page 36 Figure 4 5 WIRING DIAGRAM VS 380 460 VOLT 311USC546 01 Ref Drawing Page 3 of 4...
Страница 38: ...13 25 608 Page 37 Figure 4 5 WIRING DIAGRAM VS 380 460 VOLT 311USC546 01 Ref Drawing Page 4 of 4...
Страница 39: ...13 25 608 Page 38 Figure 4 5 WIRING DIAGRAM FS 208 230 460 VOLT 308USC546 01 Ref Drawing Page 1 of 3...
Страница 40: ...13 25 608 Page 39 Figure 4 6 WIRING DIAGRAM FS 208 230 460 VOLT 308USC546 01 Ref Drawing Page 2 of 3...
Страница 41: ...13 25 608 Page 40 Figure 4 6 WIRING DIAGRAM FS 208 230 460 VOLT 308USC546 01 Ref Drawing Page 3 of 3...
Страница 42: ...13 25 608 Page 41 Figure 4 6 WIRING DIAGRAM FS 380 415 460 VOLT 310USC546 01 Ref Drawing Page 1 of 3...
Страница 43: ...13 25 608 Page 42 Figure 4 7 WIRING DIAGRAM FS 380 415 460 VOLT 310USC546 01 Ref Drawing Page 2 of 3...
Страница 44: ...13 25 608 Page 43 Figure 4 7 WIRING DIAGRAM FS 380 415 460 VOLT 310USC546 01 Ref Drawing Page 3 of 3...
Страница 45: ...13 25 608 Page 44 Figure 4 7 WIRING DIAGRAM FS 575 VOLT 309USC546 01 Ref Drawing Page 1 of 3...
Страница 46: ...13 25 608 Page 45 Figure 4 8 WIRING DIAGRAM FS 575 VOLT 309USC546 01 Ref Drawing Page 2 of 3...
Страница 47: ...13 25 608 Page 46 Figure 4 8 WIRING DIAGRAM FS 575 VOLT 309USC546 01 Ref Drawing Page 3 of 3...
Страница 51: ...13 25 608 Page 50 Figure 4 8 PIPING AND INSTRUMENTATION ILLUSTRATIONJ 301USC797 C Ref Drawing...
Страница 75: ...13 25 608 Page 74 FIGURE9 1 Compressor Direct Drive variant Hardware Illustration 308USC810 C Ref Drawing...