13-18-612 Page 61
6-6
Figure 6- 5
– DETAILED WATER SEPARATOR AND DRAIN
The separator (4) removes the liquid water from the compressed air stream by inertial effects and
collected in a lower bowl (3). The collected water is evacuated by a float-type drain valve (1). The device
prevents the loss of compressed air by only allowing the discharge of liquid water during its opening
phase. An isolation ball valve (5) is provided between the separator bowl (3) and the drain valve body
(1). This allows the safe and quick removal of the drain valve for servicing, in case the drain valve
malfunctions.
In case the drain valve is fouled with dirt, cleanse the collection bowl also:
1. Be sure the unit is completely off and oil sump is depressurized.
2. Disconnect, lockout and tagout power supply to the compressor package.
3. Close (when provided) valve isolating compressor package from air system.
4. Unscrew drain valve (1) from isolation valve (5).
5. Unscrew collection bowl (3) from separator housing (4).
6. Inspect and clean collection bowl and sealing o-ring.
7. Reinstall in reverse order. If the vent adaptor has been removed from the bowl, note its location and
orientation in relation to the bowl (5)
– see detail Figure 6-5. The long end of the black tube attached
to the vent adaptor must protrude upward into the bowl (5) during installation. This is necessary to
promote adequate gas venting during liquid drainage.
Make sure that the isolation valve between the water separator and the drain
valve is open prior to compressor operation. Failure to do so will prevent the
drainage of separated water and will flood air lines beyond the package
discharge with water.
.
Содержание AirSmart VS80-110B
Страница 31: ...13 18 612 Page 30 4 5 Figure 4 2 PIPING AND INSTRUMENTATION ILLUSTRATION 300CGE797 A Ref Drawing...
Страница 33: ...13 18 612 Page 32 4 7 300CGE546 04 Ref Drawing Page 2 of 4...
Страница 34: ...13 18 612 Page 33 4 8 300CGE546 04 Ref Drawing Page 3 of 4...
Страница 35: ...13 18 612 Page 34 4 9 300CGE546 04 Ref Drawing Page 4 of 4...
Страница 37: ...13 18 612 Page 36 4 11 301CGE546 B Ref Drawing Page 2 of 4...
Страница 38: ...13 18 612 Page 37 4 12 301CGE546 B Ref Drawing Page 3 of 4...
Страница 39: ...13 18 612 Page 38 4 13 301CGE546 B Ref Drawing Page 4 of 4...
Страница 41: ...13 18 612 Page 40 4 15 302CGE546 05 Ref Drawing Page 2 of 4...
Страница 42: ...13 18 612 Page 41 4 16 302CGE546 05 Ref Drawing Page 3 of 4...
Страница 43: ...13 18 612 Page 42 4 17 302CGE546 05 Ref Drawing Page 4 of 4...
Страница 45: ...13 18 612 Page 44 4 19 303CGE546 B Ref Drawing Page 2 of 4...
Страница 46: ...13 18 612 Page 45 4 20 303CGE546 B Ref Drawing Page 3 of 4...
Страница 47: ...13 18 612 Page 46 4 21 303CGE546 B Ref Drawing Page 4 of 4...
Страница 70: ...13 18 612 Page 69 9 2 Figure 9 1 MINIMUM DISCHARGE PRESSURE CHECK VALVE...
Страница 86: ...NOTES...
Страница 87: ...NOTES...