Gardner Bender GMT-318 Скачать руководство пользователя страница 4

or current than the set range of the 
multimeter will allow.

4)

Do not touch the metal

probes of the test leads when making a
measurement.

5) Replace worn test leads. Do not use test

leads with broken or tattered insulation. Only
test leads meeting ETL, cETL, CE CAT II
500V IA    can be used in this multimeter.

6) Discharge a capacitor before measuring it.

7) Remove the test leads from the circuit being

measured as soon as the test is completed.

8)

Do not measure voltage

when the function/range switch is set on
the resistance (ohms) or the current (mA)
settings. Never measure current when the
meter is set on the resistance range.
Never measure AC voltage when the
meter is set on DC voltage or DCmA.
Setting the meter on the incorrect function
may burn out some of the internal circuitry
and may pose a safety hazard.

3. Operating Suggestions

1) Set the function/range switch to the proper

position before making a measurement.
When the voltage or current is not known, it
MUST be determined that the capacity of
the selected range will handle the amount of
voltage or current in the circuit (see #3
under 

For Your Safety). Always start with the

highest range in the function. If the 
reading falls within the range of a lower 
setting, reset the function/range switch to

!

WARNING

!

WARNING

6

5

the appropriate setting for greater accuracy.

2) Avoid placing the meter in areas where 

vibration, dust or dirt are present. Do not
store the meter in excessively hot, humid
or damp places. This meter is a sensitive 
measuring device and should be treated
with the same regard as other electrical
and electronic devices.

3) Using the meter in areas with high magnetic

fields can result in inaccurate readings. For
greatest accuracy, lay the meter flat on a
non-metallic surface.

4) When the meter is not in use, keep the

function/range switch in the OFF position.
This keeps the needle indicator from
deflecting or ”bouncing” excessively.

5) When disconnecting the test leads from

the unit, always grasp the leads where the
input jacks meet the meter housing. Never
pull the leads out of the jacks by the 
insulated wire or transport the meter using
the test leads as a carrying strap.

6) Never immerse the meter in water or 

solvents. To clean the housing use a damp
cloth with a minimal amount of mild soap.

7) If the resistance (ohms) function of the

meter is not going to be used for a week or
more, remove the internal battery to avoid
potential leaks that may damage the unit.

3.1 Preliminary Adjustments

Fully seat the test leads in the correct input
jacks. If necessary, using a small flat tip 
screwdriver, slowly turn the mechanical zero

GMT-318 

0415

Содержание GMT-318

Страница 1: ...propietario antes del uso y cons rvelo como referencia Avant de se servir du multimetre lire attentivement le present manuel d utilisation et le conserver GMT 318 Analog Multimeter Owners Manual Mult...

Страница 2: ...cal Zero Adjust Screw Zero Ohms Adjust ment Input Jacks Function Range Selector Switch Contents 1 Introduction 1 1 Meter Functions 2 Specifications 2 1 For Your Safety 3 Operating Suggestions 3 1 Prel...

Страница 3: ...f range AC voltage 5 full scale of range Resistance 4 arc of scale length Sensitivity 2000 ohms per volt DC and AC Function Range Switch 6 functions 15 positions 14 measuring ranges Zero Ohms Adjustme...

Страница 4: ...lower setting reset the function range switch to WARNING WARNING 6 5 the appropriate setting for greater accuracy 2 Avoid placing the meter in areas where vibration dust or dirt are present Do not sto...

Страница 5: ...s used for the DC voltage setting Decibel Gain dB see pg 14 Use the scale marked dB to read decibels for transistor gain Use the chart at the right of the scale for proper conversion 3 2 Internal Batt...

Страница 6: ...d range following multiply setting scale reading by 250 0 250 1 Common DC Milliamperage Measurements It is important to point out that milliamps can also be expressed as thousandths of an Ampere there...

Страница 7: ...testing POWER MUST BE OFF 1 Fully seat the test leads in the input jacks black lead red lead 2 Set the function range switch to the desired position and short the test leads together Using the zero oh...

Страница 8: ...fuse On plug type fuses touch the the test leads on the bottom contact and the other on the threaded metal contact see fig 6 7 3 Switches Cut off the power source to the switch If necessary remove th...

Страница 9: ...o the battery as before Read the 0 10 scale to determine the condition of the battery 10 Battery and Fuse Replacement 1 Remove the screw in the back cover of the meter and carefully separate the back...

Страница 10: ...dom sticas 10 Reemplazo de la bater a y del fusible 11 Garant a 12 Descarte correcto de este producto Aguja Escala anal gica Tornillo de ajuste mec nic o a cero Ajuste a cero ohmios Enchufes Selector...

Страница 11: ...en interiores Altitud hasta 2000 m Grado de contaminaci n 2 Grado de protecci n de ingreso IP20 Importante Lea este manual del operador completamente antes de utilizar este mult metro El fin de este m...

Страница 12: ...de la escala seleccionada acepte la cantidad de voltaje o corriente del circuito vea el No 3 bajo la secci n Para su seguridad Siempre empiece con la escala m s alta en la funci n Si la lectura cae de...

Страница 13: ...de voltaje DC pero use la escala que se encuentra directamente abajo de los n meros Miliamperios DC Utilice la misma escala y procedimientos que los usados para la posici n de voltaje DC Ganancia en...

Страница 14: ...ult metro para efectuar la medici n Si el indicador de aguja se desv a a la izquierda invierta los conductores de prueba 250 0 250 1 Mediciones comunes de corriente continua en mA Es importante se ala...

Страница 15: ...recept culo vea la fig 3A La lectura de la aguja debe ser de 120 voltios AC en la escala de 0 250 Para probar que el recept culo est debidamente conectado a tierra toque uno de los conductores de pru...

Страница 16: ...vo aseg rese de que haga buen contacto Si la aguja a n no se mueve el cable est roto y deber reemplazarse 7 2 Fusibles Nota Con el suministro el ctrico apagado OFF siempre retire un fusible del z calo...

Страница 17: ...ara determinar el estado de la bater a 10 Reemplazo de la bater a y del fusible 1 Retire el tornillo en la tapa posterior del probador y separe cuidadosamente la tapa posterior de la delantera 2 Obser...

Страница 18: ...usible 11 Garantie 12 Fa on appropri e de jeter ce produit 1 Pr sentation Le GMT 318 est un multim tre analogique capable de mesurer 6 fonctions sur 14 plages Une chelle miroir est fournie afin de r d...

Страница 19: ...onditions suivantes Pour utilisation l int rieur Altitude jusqu 2000 m Degr de pollution 2 Indice de protection d entr e IP20 Important Avant d utiliser le multim tre lire attentivement ce manuel Il c...

Страница 20: ...limite nominale suffisante pour permettre de mesurer la tension ou l intensit du circuit voir S curit n 3 Toujours commencer avec la gamme la plus lev e d une fonction Si la valeur mesur e appartient...

Страница 21: ...er l chelle 50 V puis multiplier la mesure par 10 Tension c a AC V Utiliser les m mes nombres et proc dures que pour la tension c c mais consulter l chelle qui se trouve directement au dessous des nom...

Страница 22: ...ure d intensit c c mA 1 Enfoncer les fils d essai enti rement dans les prises d entr e appropri es fil noir fil rouge 2 R gler le commutateur fonction plage au r glage 250 CC mA 3 Appliquer les fils d...

Страница 23: ...entes sous tension et neutre de la prise voir fig 3A L aiguille doit indiquer 120 V c a sur l chelle de 0 250 Pour s assurer que la prise est correctement mise la terre mettre une sonde d essai en con...

Страница 24: ...ouveau obtenir un bon contact Si l aiguille ne bouge toujours pas il existe une rupture dans la rallonge et celle ci doit tre remplac e 7 2 Fusibles Remarque apr s avoir coup l alimentation toujours r...

Страница 25: ...u ci haut Lire l chelle 0 10 afin de d terminer l tat de la pile 10 Remplacement de la pile et du fusible 1 Retirer la vis du couvercle arri re et le s parer avec pr caution du devant du bo tier 2 Not...

Страница 26: ...Gardner Bender Milwaukee WI 53209 Questions or comments 800 624 4320 www gardnerbender com Made in China Hecho en China Fabriqu en Chine GMT 318 0415...