Zone Type Terminology
The terminology used for the various zone types are explained in this section.
12 Hour
Zone active when Control Panel is Set
Access
Will allow to pass through on Exit.
Will allow to pass through on entry only if entry/exit is opened first
24 Hour
Internal sounder if Unset.
Full alarm if Set.
Entry/Exit
Zone used as last exit point
Will start entry time when opened if panel is Set
Part E/E
As Access if Control Panel is Full Set
As entry/exit if Control Panel is Part Set
P.A
24 Hour Personal Attack. Active if Control Panel is Set or Unset
Alert
Internal sounder only
Recorded to Log
Fire
Will give Fire alarm when activated (pulsed sounders) with panel set
or unset.
Exit Terminator
With Panel programmed to set with exit terminator the panel will only
set when zone is activated during exit.