background image

GARDTEC 

580

ENGINEERS MANUAL

Page 10

System Programming

The system may be programmed by the engineer by use of the engineer code (1234
factory default). Other functions are also available to the engineer, these are as fol-
lows.

Set
The engineer may fully set the system or partset the system.

Unset
The engineer may only unset the system using the engineer code if it has previously
been set using the engineer code.

Remove
The engineer may remove individual zones when setting the system.

Test 
The engineer may use this function to test the system.

Log
Using this function the engineer may read the log. The log will be shown on a last
event first basis.

Chime
Using this function the engineer may turn the chime function on and off. It should be
noted that chime zones must first be programmed from the engineer zone option.

The above options will be dealt with in the section Engineer Modes

Fig 6. shows the flow chart to be used when programming the GARDTEC 

580

580 Eng PR2945.QXD  07/03/01  16:19  Page 13

Technical Manuals Online! - http://www.tech-man.com

Содержание Gardtec 500 series

Страница 1: ...Instructions G G G GA A A AR R R RD D D DT T T TE E E EC C C C 5 5 5 5 0 0 0 0 0 0 0 0 S S S S E E E E R R R R I I I I E E E E S S S S 580 Eng PR2945 QXD 07 03 01 16 19 Page 1 Technical Manuals Onlin...

Страница 2: ...GARDTEC 580 ENGINEERS MANUAL 580 Eng PR2945 QXD 07 03 01 16 19 Page 2 Technical Manuals Online http www tech man com...

Страница 3: ...ult Modes 9 System Programming 10 Programming Charts 12 Sample programming Session 15 Engineer Modes 19 Setting the System 20 Removing Zones 21 Testing the System 22 Viewing the Log 23 Setting Chime O...

Страница 4: ...inals within one of the keypads All detection and output wiring is taken directly to the Control Panel which also incor porates a 220 240V a c connection A transformer and adequate space for a recharg...

Страница 5: ...hough the main P C B Printed Circuit Board is protected by the plastic moulding we would recommend that it is removed until the rear portion of the Control Panel is fixed to the wall To do this remove...

Страница 6: ...t to the wall easier Fig 1 GARDTEC 580 Backplate KEY A Mains entry H Cover fixing screw B Low voltage cable entry x4 J Speaker enclosure C Mains connector K Transformer D P C B Supports x4 L P C B Ret...

Страница 7: ...to comply with the requirements of B S 4737 this should be via a 3 Amp unswitched fused spur This is shown in Fig 2 below Fig 2 Mains Supply Connection Consumer Unit On Off 3A Unswitched Spur L E N Co...

Страница 8: ...ES N C DEVICES N C DEVICES N C DEVICES N C DEVICES N C DEVICES N C DEVICES N O DEVICE N O DEVICE N C TAMPER LOOP STROBE LIGHT 12V DETECTOR SUPPLY SPEAKER PROGRAMMABLE SW TO LATCH TERMI NALS ON GARDSCA...

Страница 9: ...other uses as shown in PGM2 if required PGM 2 Terminal This terminal provides a switched 12V output and is programmable by the engineer from the list below The terminal would normally be used with lat...

Страница 10: ...ilable from these terminals see power supply rating above Strobe Terminals This pair of terminals are the output for the strobe light The negative terminal is switched during an alarm period It should...

Страница 11: ...a port and remote keypad s we would advise that all keypads are in a daisy chain format Full instructions for connection are included with the RKPs ProDigi Communicator The ProDigi communicator may be...

Страница 12: ...engineer Enter the factory default user code 5678 to stop the sounder If you wish to re program the user code enter this code again to enter user mode and follow the user instructions for changing us...

Страница 13: ...engineer may remove individual zones when setting the system Test The engineer may use this function to test the system Log Using this function the engineer may read the log The log will be shown on...

Страница 14: ...Unset This is engineer mode Enter new value here Option to set This is the existing option value Do you wish to use engineer mode Press YES Press NO Enter option number then YES Enter new value then...

Страница 15: ...4 Full Set Chime 5 Fire 5 Part1 Chime 6 Alert 6 Part2 Chime 7 Exit Term 7 Part 1 2 Chime 8 Part E E The terminology used for zone types is given on page 35 As Zone1 Options As Zone1 Options As Zone1...

Страница 16: ...0 All Parts silent 0 Pulse On 1 Part 2 silent 1 SW 2 Parts1 3 silent2 Pulse Off 3 All Parts 3 Bell Audible 4 Strobe 5 Entry Exit 6 Test 7 Int Alarm 00 99seconds 00 99seconds ALERT KEYS LEFT DIGIT RIG...

Страница 17: ...T P A OUTPUT 2 PGM2 LEFT DIGIT RIGHT DIGIT 0 Audible P A 0 Pulse On 1 Silent P A 1 SW 2 Pulse Off 3 Bell 4 Strobe 5 Entry Exit 6 Test 7 Int Alarm RESET MODE LEFT DIGIT RIGHT DIGIT Always 0 0 Any Code...

Страница 18: ...etting the unit back to factory defaults will not reset the engineer code Page 15 Action Enter the Engineer Code Press YES Enter 3 option for zone3 attributes followed by YES Press NO Enter 14 E E Ful...

Страница 19: ...w act as Fire pulsed sounders Display Shows Result This is the current attribute for option 4 This allows a new value to be entered This has now returned us to the point where an option number is ente...

Страница 20: ...ult This is the current attribute for option 17 This allows a new value to be entered This has now returned us to the point where an option number is entered This is asking do you want to set the syst...

Страница 21: ...mistake has been made or the codes do not match In cases were no tone is generated the code will not be updated We have now finished this programming session Press 0 quit to return the system to unset...

Страница 22: ...Goto Page 11 If YES Goto Page 21 If YES Goto Page 22 If YES Goto Page 23 If YES Goto Page 24 If YES Goto Page 25 KEY TO SCREENS Un Unset En Engineer Mode SE Set r E Remove Zones t E Test System Lo Re...

Страница 23: ...Removed If YES was Pressed If 1 was Pressed Note When the system starts to set a short delay will be noticed before the exit sounder is activated This delay allows lower levels of codes to silent part...

Страница 24: ...de Enter Zone No to be removed then YES Repeat if required or Press 0 to escape Press YES to set with zones removed System set with zones removed Repeat Note To Un remove a zone that may have been rem...

Страница 25: ...t in this mode any zones violated will generate a tone and be displayed Pressing 9 whilst in this mode will sound the Bells and acti vate the strobe Press 9 again to stop the bell test Press 0 to esca...

Страница 26: ...e The last event will be dis played first to move back to the previous event press NO To move forward to the next event press YES A complete list of Log display messages is given in the section Log Me...

Страница 27: ...gineer Modes Setting Chime On Off Fig 12 Setting Chime On Off From page 19 May show On May show Off Press NO Press 0 to escape to Press 0 to escape to 580 Eng PR2945 QXD 07 03 01 16 19 Page 27 Technic...

Страница 28: ...digit code again Then YES Press 0 to escape to This is now asking you to repeat your new code Note To change the engineer code this option MUST be accessed from the engi neer code Note If your new fou...

Страница 29: ...stem Anti Code The system may only be reset by use of an Anti Code To Reset System Enter Code of correct type see above Proceed to set the system If a set is not required re enter the code to abort se...

Страница 30: ...Zone 3 Attributes Option No 3 This option allows the zone type zone part set remove and zone chime features to be programmed for zone 3 Zone 4 Attributes Option No 4 This option allows the zone type...

Страница 31: ...ay be looked at as three events Entry time 1 will give the normal Entry tone Entry time 2 will give a louder warning tone After both time1 time 2 has expired the external sounders will sound This opti...

Страница 32: ...battery under all circumstances The Bell Tamper mode is also programmed using this option P A Output 2 Mode Option No 20 The P A may be programmed for silent or audible using this option The output m...

Страница 33: ...RKP Tamper E O L resistor missing or cable cut to RKPs Ac Anti Code reset required Engineer reset will override PL Line fault Fail to communicate Display Messages Status Un System is Unset Day Mode E...

Страница 34: ...m Part 2 Set S System Part 3 Set o1 Unset User 1 o2 Unset User 2 o3 Unset User 3 o4 Unset User 4 o5 Unset User 5 o6 Unset User 6 o7 Unset User 7 o8 Unset User 8 o9 Unset User 9 o0 Unset User 0 Enginee...

Страница 35: ...ne and 0V Link out the tamper loop that is displaying the fault and recheck If all is O K test con tinuity of the faulty loop Also check for short circuits to other cores of the cable Check for short...

Страница 36: ...s not facing a window or situated in a draughty location In the case of a shock sensor ensure that it is not bridging any joints In the case of a contact check the gap and that there is no excessive m...

Страница 37: ...mA Quick Blow Low Voltage Output 13 8V typical Regulated Power Supply Rating 1A Battery Sizes 12V 1 2A 12V 3 0A 12V 7 0A Construction 3mm Polycarbonate Complies with B S 4737 Number of Zones 7 Tamper...

Страница 38: ...exit point Will start entry time when opened if panel is Set Part E E As Access if Control Panel is Full Set As entry exit if Control Panel is Part Set P A 24 Hour Personal Attack Active if Control P...

Страница 39: ...GARDTEC 580 ENGINEERS MANUAL 580 Eng PR2945 QXD 07 03 01 16 19 Page 39 Technical Manuals Online http www tech man com...

Страница 40: ...e OL11 1TQ United Kingdom Tel 01706 510000 Fax 01706 510100 Technical Support Tel 01706 510200 Technical Support Fax 01706 510204 Mon Fri 09 00 17 30 PR2945 REV2 0 580 Eng PR2945 QXD 07 03 01 16 19 Pa...

Отзывы: