STYLE
User’s manual
4
3
STYLE (ROOM 1)
Door panel 1
Lock 1
Wiring diagram:
Two door panels and two locks connection to the Style monitors system
OK
PWR1
GND
AD1
VD1
KEY1
PWR2
GND
AD2
VD2
KEY2
DATA
AD-1
VD-1
GND
GND
+V
B
G
A
V
D/O
D/O
Door panel 2
Lock 2
B
G
A
V
D/O
D/O
Input 1
Input 2
Input 3
Power adaptor
~ 230V / +14.5V
12V
12V
Keys:
GND
- Ground (black wire)
AD
-
Audio (blue wire)
VD
-
Video (yellow wire)
PWR
-
Power (red wire)
DATA
-
Data (green wire)
KEY
-
Open lock active 12V
(brown wire)
Input 2 and Input 3 are multifunctional, you can conect door panel or camera on this inputs. Camera can be
connected to VD - video and GND - ground wire. Choose the right device you use in settings menu.
DATA
AD-1
VD-1
GND
Input 3
STYLE (ROOM 2)
DATA
AD-1
VD-1
GND
Input 3
STYLE (ROOM 3)
DATA
AD-1
VD-1
GND
Input 3
STYLE (ROOM 4)
Installation instructions
A) Cable connection
1. Connect the monitor to the camera according to the wiring diagram.
2. Carefully insert the wires to the terminal, taking care that the 2 bare wires do not touch.
B) Installation height
Recommended installation height is approximately 140cm for monitor unit and 150cm
for outdoor camera.
C) Installation of the monitor
1. Fix the wall mounting bracket in the best place by using screws and plugs.
2. Carefully place the indoor monitor against the bracket and gently push down the
monitor so that the pins on the bracket engage in the slots on the rear of the monitor.
Cable recommendations:
If cable length between monitor and door panel not more than 30m then you can use
4-wire or 6-wire cable with 0,75 sq.mm. area of one wire. If this length exceeds 30m then
you should use coaxial cable for video (for example RG69), all other connections 4-wire or
6-wire cable can be used.
ATTENTION!
Depending on monitor position in the system (If more then one monitor is used), right
intercom address should be set for every monitor. Main monitor (all cameras and door
panels are conected to the main monitor) intrcom address should be set
ROOM1.
Additional monitors
ROOM2
,
ROOM3
and
ROOM4
intercom adresses should be used.
If there is only one monitor in the system, then intrcom address should be set ROOM1.
Attention!
Don't connect powerful devices (such as locks and CCD cameras with infrared backlight)
directly to the power supply of door camera. It can cause damage to the monitor with
no warranty providing. You should use external power supply for such powerful devices.
Maximum current for door panel power is 300mA.