background image

STYLE

User’s manual

4

3

STYLE (ROOM 1)

Door panel 1

Lock 1

Wiring diagram:

Two door panels and two locks connection to the Style monitors system 

OK

PWR1
GND
AD1
VD1
KEY1

PWR2
GND
AD2
VD2
KEY2
DATA
AD-1
VD-1
GND

GND
+V

B
G
A
V
D/O
D/O

Door panel 2

Lock 2

B
G
A
V
D/O
D/O

Input 1

Input 2

Input 3

 Power adaptor
~ 230V / +14.5V

12V

12V

Keys:

GND

 - Ground (black wire)

AD

 - 

Audio (blue wire)

VD

 - 

Video (yellow wire)

PWR

 - 

Power (red wire)

DATA 

Data (green wire)

KEY

 - 

Open lock active 12V

    (brown wire)

Input 2 and Input 3 are multifunctional, you can conect door panel or camera on this inputs. Camera can be 

connected  to VD - video and GND - ground wire. Choose the right device you use in settings menu.

DATA
AD-1
VD-1
GND

Input 3

STYLE (ROOM 2)

DATA
AD-1
VD-1
GND

Input 3

STYLE (ROOM 3)

DATA
AD-1
VD-1
GND

Input 3

STYLE (ROOM 4)

Installation instructions

A) Cable connection

1.  Connect the monitor to the camera according to the wiring diagram.

2.  Carefully insert the wires to the terminal, taking care that the 2 bare wires do not touch.

B) Installation height

Recommended installation height is approximately 140cm for monitor unit and 150cm 

for outdoor camera. 

C) Installation of the monitor

1.  Fix the wall mounting bracket in the best place by using screws and plugs. 

2.    Carefully  place  the  indoor  monitor  against  the  bracket  and  gently  push  down  the 

monitor so that the pins on the bracket engage in the slots on the rear of the monitor.

Cable recommendations:

If cable length between monitor and door panel not more than 30m then you can use 

4-wire or 6-wire cable with 0,75 sq.mm. area of one wire. If this length exceeds 30m then 

you should use coaxial cable for video (for example RG69), all other connections 4-wire or 

6-wire cable can be used.

ATTENTION!

Depending on monitor position in the system  (If more then one monitor is used), right 

intercom address should be set for every monitor. Main monitor (all cameras and door 

panels are conected to the main monitor) intrcom address should be set 

ROOM1.

Additional monitors 

ROOM2

ROOM3

 and 

ROOM4

 intercom adresses should be used.

If there is only one monitor in the system, then intrcom address should be set ROOM1.

Attention! 

Don't connect powerful devices (such as locks and CCD cameras with infrared backlight) 

directly to the power supply of door camera. It can cause damage   to   the  monitor with 

no warranty providing. You should use external power supply for such powerful devices. 

Maximum current for door panel power is 300mA.