The air filter is dirty. Clean the air filter. 

 

There are carbon deposits in the cylinder exhaust pipe or the muffler. Clean those or 
change the muffler. 

12.2 

Starting a flooded engine 

 

Disconnect the spark plug lead, and use the plug wrench to remove the spark plug in a 
counter clockwise direction. 

 

If the spark plug is fouled or is soaked with fuel, clean or replace the plug as required. 

 

Clean excess fuel from the combustion chamber by cranking the engine several times 
while the spark plug is removed. 

 

Install the spark plug and firmly tighten it with the spark plug wrench. 

 

Repeat the starting procedure as if the blower was already warm. 

12.3 

If the engine won’t stop 

If the engine continues to run after switching the on/off switch to off, stop the engine by 
pushing the choke lever to the fully closed position. If this condition continues, have the 
blower serviced before using it again. 

13  WARRANTY 

 

This product is warranted as provided by law for a 36 -month period effective from the 
date of purchase by the first user. 

 

This warranty covers all material or production flaws excluding : batteries, chargers, 
defective parts subject to normal wear & tear such as bearings, brushes, cables, and 
plugs, or accessories such as drills, drill bits, saw blades, etc. ; damage or defects 
resulting from maltreatment, accidents or alterations; nor the cost of transportation. 

 

Damage and/or defects resulting from inappropriate use also do not fall under the 
warranty provisions. 

 

We also disclaim all liability for any bodily injury resulting from inappropriate use of the tool. 

 

Repairs may only be carried out by an authorised customer service centre for Powerplus 
tools. 

 

You can always obtain more information at the number 00 32 3 292 92 90. 

 

Any transportation costs shall always be borne by the customer, unless agreed otherwise 
in writing. 

 

At the same time, no claim can be made on the warranty if the damage of the device is the 
result of negligent maintenance or overload. 

 

Definitely excluded from the warranty is damage resulting from fluid permeation, excessive 
dust penetration, intentional damage (on purpose or by gross carelessness), inappropriate 
usage (use for purposes for which the device is not suitable), incompetent usage (e.g. not 
following the instructions given in the manual), inexpert assembly, lightning strike, 
erroneus net voltage. This list is not exhaustive. 

 

Acceptance of claims under warranty can never lead to the prolongation of the warranty 
period nor commencement of a new warranty period in case of a device replacement. 

 

Devices or parts which are replaced under the warranty  therefore remain the property of 
Varo NV. 

 

 We reserve the right to reject a claim whenever the purchase cannot be verified or when it 
is clear that the product has not been properly maintained. (Clean ventilation slots, carbon 
brushes serviced regularly, etc.). 

 

Your purchase receipt must be kept as proof of date of purchase. 

 

Your appliance must be returned undismantled to your dealer in an acceptably clean state, 
(in its original blow-moulded case if applicable to the unit), accompanied by proof of 
purchase. 

Содержание POWERPLUS POWXG4060

Страница 1: ...of fire and burn injuries 5 8 OPERATION 5 8 1 Start the engine 5 8 2 To stop the engine 6 8 3 Operate the blower 6 9 CLEANING AND MAINTENANCE 6 9 1 Replacing and cleaning the air filter 6 9 2 Clean F...

Страница 2: ...se 15 Spark plug 16 Tube locking clamp 17 Air filter 18 Guide handle 3 PACKAGE CONTENT LIST Remove all packaging materials Remove remaining packaging and packing inserts if included Check that the pac...

Страница 3: ...tion before operating this production and save this instruction Do not allow children or untrained individuals to use the unit Do not start or run the engine in a closed area breathing exhaust fumes c...

Страница 4: ...t Move 30 feet 9 m away from refueling site before starting engine Never attempt to burn off spilled fuel under any circumstance Maintain the unit per maintenance instructions in this Operator s Manua...

Страница 5: ...fuel cap You can hang the leaf blower on a sturdy bench to fill with fuel 4 Unscrew the fuel tank cap and pour the mixture into the tank with the aid of a funnel Fig 5 6 5 Be careful not to spill any...

Страница 6: ...blower with the upper handle in your right hand When blow push the trigger lock to lock the trigger on height speed To keep from scattering debris blow around the outer edges of a debris pile Never bl...

Страница 7: ...plug wrench to remove the spark plug by turning it counter clockwise Fig 18 Clean and adjust the spark plug gap to 0 6 0 7mm Replace any damaged or visibly worn plug with a TORCH L8RTC or equivalent...

Страница 8: ...lso do not fall under the warranty provisions We also disclaim all liability for any bodily injury resulting from inappropriate use of the tool Repairs may only be carried out by an authorised custome...

Страница 9: ...n conformity with the essential requirements and other relevant provisions of the applicable European Directives based on the application of European harmonized standards Any unauthorized modification...

Отзывы: