Noise emissions measured in the environment as sound power
7
: R160Li, R160LiC,
R200Li, R200LiC
Measured sound power noise level, dB (A)
58
Guaranteed sound power noise level, dB (A)
60
Sound pressure noise level at the operator’s ear
8
, dB (A)
47
The noise emission declarations conforms to EN 50636-2-107:2015
Mowing
: R160Li, R160LiC,
R200Li, R200LiC
Cutting system
3 pivoted cutting blades
Blade motor speed, rpm
2300
Power consumption during cutting, W +/- 20 %
25
Cutting height, cm / in.
2-6 / 0.8-2.4
Cutting width, cm / in.
22 / 8.7
Narrowest possible passage, cm / in.
60 / 24
Maximum slope for cutting area, %
35
Maximum slope for boundary wire, %
15
Maximum length boundary wire, m / ft.
800 / 2600
Maximum length guide loop
9
, m / ft.
400 / 1300
IP-classification
: R160Li, R160LiC,
R200Li, R200LiC
Product
IPX4
Charging station
IPX1
Power supply
IPX4
Internal SRD (short range device)
R160Li, R200Li
R160LiC, R200LiC
Operating frequency band, MHz
-
863-870
Maximum transmitted power, dBm
-
25
Free field radio range, approx. m
-
100
7
Noise emissions in the environment measured as sound power (L
WA
) in conformity with EC di-
rective 2000/14/EC and New South Wales legislation (Protection of the Environment Operations
Regulation 2017, Noise Control). The guaranteed sound power level includes variation in pro-
duction as well as variation from the test code with 1-3 dB(A). Noise emission data can be found
on the rating label and in the Technical data chapter.
8
Sound pressure noise uncertainties K
pA
, 2-4 dB (A)
9
A guide loop is the connection between the guide wire, boundary wire and the connection on the
right connector on the charging station.
50 - Technical data
1378 - 003 - 16.04.2020