The baseplate of the charging station must
not be bent.
max. 5 cm / 2"
max. 5 cm / 2"
•
Put the charging station in the lower section
of the work area.
•
Put the charging station in an area with
protection from the sun.
•
If the charging station is installed on an
island, make sure to connect the guide wire
page 17.
3.4.2 To examine where to put the power
supply
WARNING: Do not cut or extend the
low-voltage cable. There is a risk of
electrical shock.
CAUTION: Make sure that the blades
on the product do not cut the low-
voltage cable.
CAUTION: Do not put the low-voltage
cable in a coil or below the charging
station plate. The coil causes
interference with the signal from the
charging station.
•
Put the power supply in an area with a roof
and protection from the sun and rain.
•
Put the power supply in an area with good
airflow.
•
Use a residual-current device (RCD) when
you connect the power supply to the power
outlet.
Low-voltage cables of different lengths are
available as accessories.
3.4.3 To examine where to put the
boundary wire
CAUTION: There must be an obstacle
of minimum 15 cm / 6 in. in height
between the boundary wire and water
bodies, slopes, precipices or public
roads. This will prevent damage to the
product.
CAUTION: Do not let the product
operate on gravel.
CAUTION: Do not make sharp bends
when you install the boundary wire.
CAUTION: For careful operation
without noise, isolate all obstacles
such as trees, roots and stones.
The boundary wire should be put as a loop
around the work area. Sensors in the product
senses when the product approaches the
boundary wire, and the product selects another
direction. All parts of the work area must be
maximum 35 m / 115 ft. from the boundary wire.
To make the connection easier between the
guide wire and the boundary wire, it is
recommended to make an eyelet where the guide
1378 - 003 - 16.04.2020
Installation - 15