GB
14
Clean the pump :
7. Troubleshooting
DANGER ! Electric shock !
A
V
Disconnect the pump from the mains before
working on it !
FSP 3500 :
1. Remove pump from the filter housing (see 6. Maintenance).
2. Turn pump housing
8
anti-clockwise and pull vertically off the
motor housing
9
(bayonet fitting).
3. Clean the motor housing
9
and pump housing
8
.
4. Pull the impeller unit
A
out of the motor housing
9
clean and
push back into the motor housing
9
.
5. Press pump housing
8
vertically onto the motor housing
9
and turn clockwise (bayonet fitting).
FSP 5500 Economic / FSP 8500 Economic :
1. Remove pump from the filter housing (see 6. Maintenance).
2. Undo screws
F
and remove pump housing
8
.
3. Pull the impeller unit
A
out of the motor housing
9
clean and
push back into the motor housing
9
.
4. Clean the motor housing
9
and pump housing
8
.
5. Press pump housing
8
upright onto the motor housing
9
and fit the screws
F
.
During assembly, pay attention that the O-ring
B
is correctly
placed in the motor housing
9
.
FSP 12000 Economic / FSP 16000 Economic :
1. Remove pump from the filter housing (see 6. Maintenance).
2. Unscrew and clean collar
C
along with foam plastic
D
and O-ring
E
.
3. Undo screws
F
and remove pump housing
8
.
4. Pull the impeller unit
A
out of the motor housing
9
clean and
push back into the motor housing
9
.
5. Clean the motor housing
9
and pump housing
8
.
6. Press pump housing
8
upright onto the motor housing
9
and fit the screws
F
.
During assembly, pay attention that the gasket
B
is correctly
placed in the motor housing
9
.
7. Screw on collar
C
along with foam plastic
D
and O-ring
E
.
During assembly, pay attention that the O-ring
E
is correctly
placed in the pump housing
8
.
9
8
A
B
F
8
9
A
F
B
F
8
9
A
F
B
F
C
E
8
9
A
D
F
FSP 3500
FSP 5500 Economic
FSP 8500 Economic
FSP 12000 Economic /
FSP 16000 Economic
7862-20.960.02_05.08.2008:GARDENA
05.08.2008
09:09
Seite 14