background image

10

GB

Commissioning the Pond Filte r :

Cleaning the Filter :

B

C

A

E

D

3

6

7

1

F

0

3

1

9

8

5

4. Initial Operation 

A Commissioning the Pond Filter and Fountain :

1. Place the Pond Filter and Fountain on a firm base so that the

filter housing 

7

is fully covered with water (max. 2 m under

water).

2. Plug mains plug into an AC power socket.

Warning: Pump will start immediately.

3. Adjust the water flow with the regulating 

valves 

5

8

so that the flow rate is 

correct for the fountain / gargoyle.

4.

Water Bell, Fleur-de-Lis and Water Jet :

screw the fountain insert into the nozzle 
tube until the fountain achieves the 
desired shape.

Note :

The ball joint 

9

can be used to 

compensate for uneven ground.

B Commissioning the Pond Filter and stepped nipple :

1. Place the Pond Filter and stepped nipple on a firm base so that

the filter housing 

7

is fully covered with water (max. 2 m under

water).

2. Plug mains plug into an AC power socket.

Warning: Pump will start immediately.

5. Maintenance 

Warning ! Electric shock ! 

Disconnect the pump from the mains before working on it.

Do not use any hard objects or powerful detergents for cleaning
the set! 

1. Take the Pond Filter out of the water and unscrew the nozzle

tube 

1

/ stepped nipple 

6

.

2. Release the catches 

0

and take out the filter housing 

7

.

3. Remove the pump 

A

from the filter block 

B

.

4. Remove filter gravel 

C

and biological surface filter 

D

and both

the filter surrounds 

E

.

5. Wash out the filter housing 

7

, filter block 

B

,  gravel 

C

and 

filter surrounds 

E

under running water.

6. Place the biological surface filter 

D

in clean water (do not wash

it under running water).

7. Reassemble the Pond Filter in the reverse order. Be sure to

route the cable in its guides 

F

.

7

7

Содержание FFP 3000

Страница 1: ... NL Gebruiksaanwijzing Vijverfilter met waterspelpomp set S Bruksanvisning Dammfilter med pumpset för fontän I Istruzioni per l uso Filtro per laghetti con set di pompe per giochi d acqua E Manual de instrucciones Filtro para estanque con juego de bombas para efectos de agua P Instruções de manejo Conjunto de filtro para lagos com bomba de jogos de água DK Brugsanvisning Damfilter med springvandsp...

Страница 2: ...utdoor garden ponds with and without fish stocks It is not designed for operating watering equipment or irrigation systems The GARDENA Pond Filter and Fountain Pump Set is not suitable for continuous operation in industrial applications Corrosive easily combustible aggressive or explosive sub stances e g petrol petroleum nitro thinner as well as salt water or food and drinking water must not be pu...

Страница 3: ...imming pools and garden ponds should be designed according to international and national design regula tions v Please consult a professional electrician For Austria Pumps for use on swimming pools and on ponds may only be operated via an isolating transformer v Please consult a professional electrician For Switzerland In Switzerland mobile appliances which are used outdoors must be connected via a...

Страница 4: ...he Pond Filter and stepped nipple on a firm base so that the filter housing 7 is fully covered with water max 2 m under water 2 Plug mains plug into an AC power socket Warning Pump will start immediately 5 Maintenance Warning Electric shock V Disconnect the pump from the mains before working on it Do not use any hard objects or powerful detergents for cleaning the set 1 Take the Pond Filter out of...

Страница 5: ...peller unit is blocked v Clean pump Electronic circuit breaker v Stand the pump in the has been activated water Reduced water feature Water feature insert is dirty v Clean water feature insert and nozzle pipe Filter clogged v Clean filter Pump shuts down after Water temperature too high v Maximum water a short time temperature is 35 C If any other faults arise please contact GARDENA Service 7 Stor...

Страница 6: ... 10 Service Warranty GARDENA guarantees this product for 3 years starting from the date of purchase This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults Under warranty we will either replace the unit or repair it free of charge if the following conditions apply The unit must have been handled properly and in keeping with the requirements o...

Страница 7: ...om skadan beror på att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra än Original GARDENA reservdelar har använts Samma sak gäller för kompletteringsdelar och tillbehör I Responsabilità Si rende espressamente noto che conformemente alla legislazione sulla del prodotto responsabilità del prodotto non si risponde di danni causati da nostri arti coli se originati da ri...

Страница 8: ...es le matériel neuf désigné ci dessous était conforme aux prescriptions des directives européennes énoncées ci après et conforme aux règles de sécurité et autres règles qui lui sont applicables dans le cadre de l Union européenne Toute modification portée sur ce produit sans l accord express de GARDENA supprime la validité de ce certificat N EU overeenstemmingsverklaring Ondergetekende GARDENA Man...

Страница 9: ...a di rendimento Curva característica de la bomba Características de performance Ydelses karakteristika FFP 3000 Art 7887 Pumpen Kennlinie Performance characteristics Courbes de performance Prestatiegrafiek Kapacitetskurva Curva di rendimento Curva característica de la bomba Características de performance Ydelses karakteristika ...

Страница 10: ...and Ó Johnson Kaaber Tunguhalsi 1 110 Reykjavik ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Phone 39 02 93 94 79 1 info gardenaitalia it Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku Tokyo 102 0084 m_ishihara kaku ichi co jp Phone 81 33 264 4721 Luxem...

Отзывы: