9
GB
3. Assembly
A Fit the Fountain to the Pond Filter :
1. Click the nozzle tube
1
into the ball joint
2
.
2. Screw the nozzle tube
1
on the threaded spigot on the pump.
3. Screw the desired fountain insert
3
a) / b) / c) / d)
into the
nozzle tube
1
.
a) Cascade b) Water Bell b) Fleur-de-Lis d) Water Jets
Side outlet
4
:
Additional consumers (e.g. gargoyles) can be
connected to the side outlet
4
[9 mm / 13 mm (1/ 2
”
)]. The
quantity of water can be adjusted via the regulator
5
.
B Fit the stepped nipple (
1/ 2
”
- 3 /4
”
) to the Pond Filter :
The stepped nipple
6
can be used to supply features such as a
stream or a source stone.
1. Screw the stepped nipple
6
on the threaded spigot on the
pump, having first checked that the O-Ring
z
is in place
within the stepped nipple.
2. Push the hose on to the stepped nipple
6
.
Note :
If a 3 /4
”
hose is used, the front part of the stepped nipple
can be cut off using a saw.
Installing the Pond Filter :
The pump must not be operated when there
are people in the water. Swimming pools and
garden ponds should be designed according
to international and national design regula-
tions.
v
Please consult a professional electrician.
For Austria :
Pumps for use on swimming pools and on
ponds may only be operated via an isolating
transformer.
v
Please consult a professional electrician.
For Switzerland :
In Switzerland mobile appliances which are
used outdoors, must be connected via a
residual-current device.
Note :
Do not allow the pump to run without
water because dry-running leads to an
undesirable build up of heat and will
destroy the pump.
Before operating the pump, look to see if there
is any damage to the pump (esp. regarding
power cable and plug). The connection cable
of the pump cannot be replaced. If the cable is
damaged the pump must be scrapped.
Do not use the power cable to carry the pump
or to pull the plug out of the socket.
Protect the power cable from heat, oil and
sharp edges.
The temperature of the liquid used must not
be below 4 °C or above 35 °C.
Sand and other abrasive substances in the
liquid cause increased wear and reduce the
output of the pump.
Please observe the local noise prevention
regulations.
O
1
3
2
4
5
6
z
O