background image

2. Function

The Electronic Pressure Pump is equipped with an electronic 

 control which automatically turns on the pump when the cut-in 

pressure has fallen and automatically switches off when no  

more water is extracted.

Low quantity programme 

(Leakage Warning):

The low quantity programme allows for trouble-free use of, for 

example, modern washing machines or drip irrigation systems, 

even with low water flow. Operating interval: Up to 60 minutes 

(leakage warning may be triggered after 60 minutes).

Note: The cyclical activation and deactivation of the 

 Electronic Pressure Pump in small amount mode is due  

to the system design and does not have any impact on  

pump life.

For irrigation: If the low quantity programme is to be used for 

more than 60 minutes, irrigation must be disrupted for at least 

5 minutes before the end of the 60 minute period. The small 

amount programme can then be used for a further 60 minutes.
Use of washing machines: Upon completion of the minimum 

amount water supply cycle in washing machines, the 60-minute 

operating interval of the low quantity programme is automatically 

reset to normal operation of the Electronic Pressure Pump and 

allows a trouble-free use of the washing machine for > 60 minutes.

Info-LED:

The pump is equipped with a faults diagnostics system where 

 various disturbance states can be determined by the Info LED  

(see 7. Troubleshooting).

 

3. Installation

Positioning of Electronic  

Pressure Pump:

The installation position must be firm and dry, and permit a secure 

mounting for the Electronic Pressure Pump.

 Install the Electronic Pressure Pump at a safe distance  

(min. 2 m) from the  pumping medium.

The pump must be installed in a location with an air humidity of  

< 80 % and sufficient ventilation in the area of the ventilation slots. 

It must be at a distance of at least 5 cm from the walls. No dirt 

contamination (e. g. sand or earth) may be sucked in through the 

ventilation slots.

some conditions interfere with active or passive 

medical implants. To decrease the risk of condi-

tions that can possibly injure or kill, we recom-

mend persons with medical implants to speak 

with their physician and the medical implant 

manufacturer before you operate the product.

DANGER! Small parts can be easily swallowed. 

There is also a risk that the polybag can 

 suffocate toddlers. Keep toddlers away when 

you assemble the product.

17

EN

Содержание Comfort 4000/5E

Страница 1: ...tomatico ES Instrucciones de empleo Estaci n de bombeo PT Manual de instru es Bomba de press o PL Instrukcja obs ugi Hydrofor HU Haszn lati utas t s H ztart si automata szivatty CS N vod k obsluze Dom...

Страница 2: ...the pump pressure have to be added together Example pressure at the tap 2 0 bar maximum pressure of the Electronic Pressure Pump 3500 4E 3 5 bar total pressure 5 5 bar Liquids pumped The GARDENA Elect...

Страница 3: ...powered through an isolating trans former v Please ask your electrician for his advice In Switzerland In Switzerland portable devices that are used outdoors must be connected through a residu al curr...

Страница 4: ...e is automatically reset to normal operation of the Electronic Pressure Pump and allows a trouble free use of the washing machine for 60 minutes Info LED The pump is equipped with a faults diagnostics...

Страница 5: ...n the connection fit tings with the upmost care Use sealing tape only for sealing metallic connection fittings Suction inlet Art 1723 Art 1724 4 3 2 Do not use any water hose snap connection system co...

Страница 6: ...the liquid to be pumped via the filler connection 0 up to the overflow approx 2 to 3 l until the water level no longer drops under the suction side inlet or the water flows out at the horizontal conne...

Страница 7: ...the Electronic Pressure Pump must be emptied and stored where it will not become frozen Store out of the reach of children 1 Change the switch q to O 2 Unplug the mains connection for the pump 3 Open...

Страница 8: ...t no 1758 2 Disconnect mains plug 3 If necessary close all valves on the intake side 4 Open all pressure side outlets so that the pressure side is depressurised Afterwards close the tapping points aga...

Страница 9: ...ault Indicator is deleted by switching off the pump or pulling the mains plug Problem Possible Cause Remedy Info LED blinks once During the initial operation the pump did not suck water for 30 seconds...

Страница 10: ...cuit breaker activated motor overheated v Allow the pump to cool down for 20 minutes Info LED blinks 3 times During the current operation the pump has extracted no water for 30 seconds Water supply di...

Страница 11: ...GARDENA Service Switch is not turned to I v Restart the pump see 4 Operation Mains plug not plugged in v Insert mains plug into a mains socket 230 V AC Power failure v Check fuse and cables Free the i...

Страница 12: ...For vacuum resistant connection of the pump to boreholes or pipe networks Length 0 5 m With 33 3 mm G1 female thread at both ends Art no 1729 GARDENA Connection Set Connection Set for 1 2 Pressure Ho...

Страница 13: ...ollowing provisions The product was used for its intended purpose as per the recommendations in the operating instructions Neither the purchaser nor a third party has attempted to repair the product T...

Страница 14: ...i ikke p tager os noget ansvar for skader p vores produkter hvis de p g ldende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale G...

Страница 15: ...javljujemo kako ne prihva amo nikakvu odgovornost za o te enja na na im proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekori tenja or...

Страница 16: ...acima est o em conformidade com as diretrizes uniformizadas da UE os padr es de seguran a da UE e os padr es espec ficos do produto Este certificado deixa de ser v lido se as unidades forem modificada...

Страница 17: ...anduiding M rknings r CE M rknings r CE merkin kiinnitysvuosi Anno di applicazione della certificazione CE Colocaci n del distintivo CE Ano de marca o pela CE Rok nadania oznakowania CE CE jelz s elhe...

Страница 18: ...Szivatty jellegg rbe Charakteristika erpadla Charakteristiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba karakteri...

Страница 19: ...S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku To...

Отзывы: