background image

  1. Safety Instructions   . . . . . . . . . . . . . . . . . . . 15
  2. Function   . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
  3. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 17
  4. Operation   . . . . . . . . . . . . . . . . . . . . . . . . . . 19 
  5. Storage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
  6. Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . 20
  7. Troubleshooting   . . . . . . . . . . . . . . . . . . . . . 21
  8. Available accessories  . . . . . . . . . . . . . . . . . 25
  9. Technical Data   . . . . . . . . . . . . . . . . . . . . . . 25
10.  Service / Warranty  . . . . . . . . . . . . . . . . . . . . 26

Original instructions.

Never operate the product when you are tired,  

ill or under the influence of alcohol, drugs or 

medicine. 

This product may be used under 

supervision, or if instruction 

regarding the safe use of the 

product has been provided and the 

resulting dangers have been under-

stood, by children aged 8 and above,  

as well as by persons with physical, 

sensory or mental disabilities or a lack 

of experience and knowledge. Children 

must not be allowed to play with the 

product. Cleaning and user maintenance 

must not be performed by children with-

out supervision.  The use of this product 

by young people under the age of 16 is 

not recommended.

Intended use:
GARDENA Electronic Pressure Pumps have been 

designed for  private use around the house and 

garden. Electronic Pressure Pumps are predomi-

nantly used for operating watering systems and 

systems in private gardens. 
When using the pump for pressure intensifi-

cation, the maximum permissible internal 

pressure of 6 bar (on the delivery side) must 

not be exceeded. The delivery pressure to be 

increased and the pump pressure have to  

be added together.
•  Example: pressure at the tap = 2.0 bar,  

maximum pressure of the Electronic Pressure 

Pump 3500/4E = 3.5 bar, total pressure  

= 5.5 bar.

Liquids pumped:
The GARDENA Electronic Pressure Pump can  

be used for pumping rainwater, tap water and 

chlorinated water.
IMPORTANT! The GARDENA Electronic 

 Pressure Pump is not suitable for continuous 

operation (e. g. industrial applications, con-

tinuous circulating operation). Corrosive, 

 easily combustible, aggressive or explosive 

liquids (such as gasoline, petroleum or 

 nitrothinner), saltwater and food intended  

for consumption must not be pumped.  

The temperature of the liquid must not  

exceed 35 °C. Before the beginning of the 

frost period, the Electronic Pressure Pump 

must be drained and placed in frost-proof 

storage (see 5. Storage).

GARDENA Electronic Pressure Pump  

Classic 3500/4E / Comfort 4000/5E

1. Safety Instructions

Electrical safety

 DANGER! Electric shock!

Risk of injury due to electric shock!

v

  Always unplug your pump before filling, 

after operation, before troubleshooting 

and before carrying out any maintenance 

work.

The pump must be supplied through  

a residual current device (RCD) having  

a rated residual operating current not  

exceeding 30 mA.
The pump must be located on solid, even 

ground, protected from flooding. Take care  

that the pump cannot fall into water.
As an additional safety device an approved 

safety switch can be used.

v

 Please ask your electrician for his advice.

15

EN

Содержание Comfort 4000/5E

Страница 1: ...tomatico ES Instrucciones de empleo Estaci n de bombeo PT Manual de instru es Bomba de press o PL Instrukcja obs ugi Hydrofor HU Haszn lati utas t s H ztart si automata szivatty CS N vod k obsluze Dom...

Страница 2: ...the pump pressure have to be added together Example pressure at the tap 2 0 bar maximum pressure of the Electronic Pressure Pump 3500 4E 3 5 bar total pressure 5 5 bar Liquids pumped The GARDENA Elect...

Страница 3: ...powered through an isolating trans former v Please ask your electrician for his advice In Switzerland In Switzerland portable devices that are used outdoors must be connected through a residu al curr...

Страница 4: ...e is automatically reset to normal operation of the Electronic Pressure Pump and allows a trouble free use of the washing machine for 60 minutes Info LED The pump is equipped with a faults diagnostics...

Страница 5: ...n the connection fit tings with the upmost care Use sealing tape only for sealing metallic connection fittings Suction inlet Art 1723 Art 1724 4 3 2 Do not use any water hose snap connection system co...

Страница 6: ...the liquid to be pumped via the filler connection 0 up to the overflow approx 2 to 3 l until the water level no longer drops under the suction side inlet or the water flows out at the horizontal conne...

Страница 7: ...the Electronic Pressure Pump must be emptied and stored where it will not become frozen Store out of the reach of children 1 Change the switch q to O 2 Unplug the mains connection for the pump 3 Open...

Страница 8: ...t no 1758 2 Disconnect mains plug 3 If necessary close all valves on the intake side 4 Open all pressure side outlets so that the pressure side is depressurised Afterwards close the tapping points aga...

Страница 9: ...ault Indicator is deleted by switching off the pump or pulling the mains plug Problem Possible Cause Remedy Info LED blinks once During the initial operation the pump did not suck water for 30 seconds...

Страница 10: ...cuit breaker activated motor overheated v Allow the pump to cool down for 20 minutes Info LED blinks 3 times During the current operation the pump has extracted no water for 30 seconds Water supply di...

Страница 11: ...GARDENA Service Switch is not turned to I v Restart the pump see 4 Operation Mains plug not plugged in v Insert mains plug into a mains socket 230 V AC Power failure v Check fuse and cables Free the i...

Страница 12: ...For vacuum resistant connection of the pump to boreholes or pipe networks Length 0 5 m With 33 3 mm G1 female thread at both ends Art no 1729 GARDENA Connection Set Connection Set for 1 2 Pressure Ho...

Страница 13: ...ollowing provisions The product was used for its intended purpose as per the recommendations in the operating instructions Neither the purchaser nor a third party has attempted to repair the product T...

Страница 14: ...i ikke p tager os noget ansvar for skader p vores produkter hvis de p g ldende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale G...

Страница 15: ...javljujemo kako ne prihva amo nikakvu odgovornost za o te enja na na im proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekori tenja or...

Страница 16: ...acima est o em conformidade com as diretrizes uniformizadas da UE os padr es de seguran a da UE e os padr es espec ficos do produto Este certificado deixa de ser v lido se as unidades forem modificada...

Страница 17: ...anduiding M rknings r CE M rknings r CE merkin kiinnitysvuosi Anno di applicazione della certificazione CE Colocaci n del distintivo CE Ano de marca o pela CE Rok nadania oznakowania CE CE jelz s elhe...

Страница 18: ...Szivatty jellegg rbe Charakteristika erpadla Charakteristiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba karakteri...

Страница 19: ...S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku To...

Отзывы: