Additional safety warnings
Electrical safety

  

DANGER! Cardiac arrest!

This product makes an electromagnetic field while it operates. This field 

may under some conditions interfere with active or passive medical 

implants. To decrease the risk of conditions that can possibly injure or 

kill, we recommend persons with medical implants to speak with their 

physician and the medical implant manufacturer before you operate the 

product.

  

DANGER! Electric shock!

The product must not be operated if there are people in the swimming 

pool or garden pond.

v  

Make sure that the electrical plug and socket connections are fitted in 

an area which cannot be flooded.

v  

Protect the power plug from moisture.

Connecting cable

  

DANGER! Electric shock!

With a cut off mains plug, moisture can get into electrical parts via the 

mains cable and cause a short circuit.

v

  Do not cut the mains plug off (e. g. to feed through a wall).

If the supply cord is damaged, it must be replaced by  

the manufacturer, its service agent or similarly qualified 

persons in order to avoid a hazard.

According to DIN VDE (German Electrical Engineers’ Association) 0620, mains 

power cables and extension cables must not have a smaller cross-section than 

the rubber-sheathed cables of the designation H07RN-F. 
The cable length must be at least 10 m.
Data indicated on the type plate must match technical data of the mains  

supply.
Disconnect the product from the mains when it is not in use.
Protect plug and power cable from heat, oil and sharp edges.
Do not use the power cable to carry or to unplug the pump.
As an additional safety device an approved safety switch can be used.

v  

Please ask your electrician for his advice.

Only use extension cables with earth connectors for operating this pump.
A damaged pump must not be used.
Before operating the pump look and see if there is any damage to the pump 

(especially to the power cable and plug).

v  

In case of damage, please have the pump checked by our GARDENA  

Service Centre.

Personal safety

  

DANGER! Risk of suffocation!

Small parts can be easily swallowed. There is also a risk that the poly-

bag can suffocate toddlers. Keep toddlers away when you assemble the 

product.

  

DANGER! Risk of injury due to hot water!

If the electronic control is defective or if the water supply on the intake 

side of the pump fails, any water remaining in the pump may heat up, 

generating a risk of injuries caused by hot water on leakage.

v  

Disconnect the pump from the mains, let the water cool (approx.  

10 – 15 min.) and secure the water supply on the intake side before 

putting into operation again.

Do not use the product while you are tired or under the influence of drugs, alco-

hol or medication. A moment of inattention while you operate the product may 

result in serious personal injury.
When connecting the pump to the water supply system, the country-specific 

sanitary regulations must be observed to prevent water not of drinking water 

quality being drawn back in.
When water flows through the pump it is no drinking water anymore.
When using the product, cover hair and do not wear scarves and other loose 

items of clothing.
Make sure that no children or unauthorised persons are within reach of the pump 

and the pumped medium without supervision.
In order to avoid dry-running of the pump, take care that the end of the suction 

hose is always submerged into the water.

v  

Before each operation, fill the pump with liquid to be pumped (approx. 2 to 3 l).

The pump must be located on solid, even ground, protected from flooding.  

Take care that the pump cannot fall into water.
Very fine sand can pass through the integrated filter (mesh size 0.45 mm)  

and cause accelerated wear in the hydraulic parts.

v  

For sandy water, you should additionally use the GARDENA Pump 

 Preliminary Filter, art. 1730 (mesh size 0.1 mm).

2. INSTALLATION

  

 DANGER! Electric shock!

 

Risk of injury due to electric current.

v  

Disconnect the product from the mains before you install the 

product.

Installation location [ Fig. I1 ]:

The pump must be installed in a location with sufficient venti-

lation in the area of the ventilation slots. It must be at a distance 

of at least 5 cm from the walls. No dirt contamination (e. g. sand 

or soil) may be sucked in through the ventilation slots.

Set up the pump so that it is prevented from slipping and that an appro-

priately large collecting vessel for draining the pump or the system can be 

placed under the drain screw 

(1)

.

Install the pump at a safe distance (min. 2 m) from the pumping medium.
If possible, install the pump higher than the surface of the water to be 

pumped. If this is not possible, install a vacuum-resistant shut-off device 

between the pump and the suction hose to allow the integrated filter to  

be cleaned.
If the system is permanently installed, appropriate shut-off devices must 

be installed on the input and output sides. Important for maintenance and 

cleaning work on the pump or for shutdown, for example.

Connections:

  

 CAUTION!

 

The GARDENA connection pieces on the intake and deli-

very sides may only be tightened by hand. Check whether the 

seal ring is present and undamaged before screwing the suction 

hose onto the suction inlet. When using metal connections, 

damage could occur on the connection thread due to inapprop-

riate assembly. Therefore, screw on the connection fittings  

with the upmost care. Use sealing tape only for sealing metallic 

connection fittings.

Suction side:
Do not use modular water hose components on the suction side!  

A vacuum-tight suction hose must be used e.g.:
–  GARDENA Suction Hose Art. 1411 / 1418
–  GARDENA Bore Hole Suction Hose Art. 1729
–  GARDENA Suction Hose sold by the metre with  

GARDENA Hose Clamp Art. 7192 / 7191.

If very fine dirt is present, we recommend the use of a GARDENA Pump 

preliminary filter Art. 1730 / 1731 in addition to the integrated filter.
To reduce the pump repriming time, we recommend to use a suction  

hose with backflow preventer, which prevents the suction hose emptying 

automatically when the Automatic Home & Garden Pump is switched off.

Important for fixed installation:
For greater suction heads, use a suction hose with a small diameter (3/4").

Pressure side:
A pressure-resistant hose must be used on the pressure side, e. g.:
–  GARDENA Garden Hose (3/4") Art. 18113 with  

GARDENA Connection Set Art. 1752.

Important for fixed installation:
If the product is permanently installed in an enclosed space, only flexible 

hoses (e.g. reinforced hoses) may be used for connecting the service 

water supply, rather than rigid piping. Flexible hoses will reduce the noise 

level and prevent damage caused by pressure surges. Install fixed pipes 

at an upward gradient on the first 2 m only. To avoid damage to the 

thread, ensure careful and accurate installation when using metal 

connections.

To connect the suction hose [ Fig. I2 ]:
1. Screw the suction hose fitting 

(3)

 onto the suction inlet 

(4)

 and tighten  

it by hand.

2. Slide the suction hose 

(2)

 onto the suction hose fitting 

(3)

 and secure  

it e.g. with a GARDENA Hose Clamp Art. 7192 / 7191.

The temperature of the pumped liquid must be between 2 °C to 35 °C.
Only stow the product in temperatures between 2 °C to 70 °C.

EN

9

Содержание Classic 3500/4

Страница 1: ...for elektroniczny HU Haszn lati utas t s H ztart si s kerti automata szivatty CS N vod k obsluze Dom c a zahradn automat SK N vod na obsluhu Dom ci a z hradn automat EL RU SL Navodilo za uporabo Hi ni...

Страница 2: ...dnie z niemieck ustaw o odpowiedzialno ci za produkt niniejszym wyra nie o wiadczamy e nie ponosimy adnej odpowiedzialno ci za szkody poniesione na skutek u ytkowania naszych produkt w w przypadku gdy...

Страница 3: ...3 I1 1 I2 Art 1723 Art 1724 4 3 2 I3 Art 1752 5 7 8 6 O1 0 9 A q r O2 9 A 0 a M1 12 13 11 9 A M2 1 2 12 13 M3 14 15 11 Art 1757 M4 15 14 11 Art 1758 S1 1 11 T1 q v T2 16 T3 18 17 20 22 21 19...

Страница 4: ...itrothinner saltwater and food intended for consumption must not be pumped Pressure amplification If you use the pump for pressure amplification the maximum permissible internal pressure must not exce...

Страница 5: ...mp must be located on solid even ground protected from flooding Take care that the pump cannot fall into water Very fine sand can pass through the integrated filter mesh size 0 45 mm and cause acceler...

Страница 6: ...ater To connect the pressure hose Fig I3 The pressure hose can be connected either to the delivery side 33 3 mm G1 thread of the 120 swivelling connection 5 and or of the horizontal connection 8 1 Scr...

Страница 7: ...filter lid seal and turn the lid until the stopper see 4 MAINTENANCE v Clean the filter in the pump Suction hose deformed or bent v Use a new suction hose Problem Possible Cause Remedy Pump does not s...

Страница 8: ...ENA Manufacturing GmbH offers a 2 year warranty for this product from the date of purchase if the product has been used exclusively for private purposes This manufacturer s warranty does not apply to...

Страница 9: ...pompy Szivatty jellegg rbe Charakteristika erpadla Charakteristiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba kara...

Страница 10: ...su u nastavku navedene jedinice prilikom napu tanja tvornice bile u skladu s uskla enim smjernicama EU EU sigurnosnim standardima i standardima specifi nima za proizvod Ova certifikacija poni tava se...

Страница 11: ...rdena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development K...

Отзывы: