17
GB
Only for Ambiente 48 S :
Replace fuse of transformer :
The following fuse is required :
•
Ambiente 48 S (Art. 7977) :
∅
5 x 20, 250 V, 1,6 A, T
Replacement fuses are available from GARDENA Service on
request.
1. Remove fuse cap
L
.
2. Unscrew fuse cover
M
.
3. Remove fuse
N
and insert a new one.
4. Screw fuse cover
M
back on.
5. Refit fuse cap
L
.
Problem Probable
Cause
Remedy
No radio contact
Battery in remote control spent.
v
Replace battery.
Antenna on remote control
v
Pull out antenna on
not pulled out.
remote control.
Antenna not fitted to generator.
v
Fit antenna to generator.
Mist Generator not
Cable not inserted.
v
Insert power plug.
functioning
Defective cable / connection.
v
Remove power plug and
check all outgoing
connections and cables.
Water level too low.
v
Ensure water level is
sufficient.
Use of distilled water.
v
Do not use distilled water.
(only for Ambiente 48 S)
Fuse of transformer defective.
v
Replace fuse.
Individual membrane /
Membrane unit not fully
v
Fully insert membrane
membrane unit not
inserted in generator.
unit in generator.
functioning
Membrane unit not correctly
v
Check / insert plug-in
inserted.
connection to membrane
unit.
Membrane / membrane unit
v
Replace membrane /
defective.
membrane unit.
Mist effect falls off
Membranes soiled.
v
Clean or replace
membranes.
A
In the event of other faults please contact GARDENA Service. Repairs should only
be carried out by GARDENA service centres or dealers authorised by GARDENA.
M
N
L