background image

7. [ Fig.  O13 ]:  Select the minutes for watering 

duration using the 

-

 keys (e. g. 

20  

20  

minutes) 

and confirm by pressing the OK key. 

24 h blinkt.

Setting the watering cycle / watering days:

a)   Watering cycle: 

Watering options are every 24 hours “24h”, 

every second day “2nd”, every third day “3rd”, 

every “Odd” day odd or every even day 

Even”.

b)  Watering days: 

Every day Mo, Tu, We, Th, Fr, Sa, Su can be 

individually set.

  8.  a) [ Fig.  O14 ]:  Watering cycle: 

Using the 

-

 keys, select the desired watering 

cycle  (e. g.  2nd = every 2nd day) and confirm 

by pressing the OK key. 

The watering cycle (e. g. 2nd ) and the preview 

for the week (e. g.  Su ,  Tu ,  Th ,  Sa  ) are 

shown on the display in frames.

The days in the preview for the week are 

always with respect to the day of the week set 

in the system (e. g. Sunday Su).

 

– or –

  

b) [ Fig. O15 ]: Watering days: 

Using the 

-

 keys, select the desired day  

of the week (e. g. Mo = Monday) and select /  

deselect the day by pressing the OK key.  

The selected watering days (e. g. MoWe,  Fr  ) 

are shown on the display in frames.

 9. [ Fig.  O16 ]:  Press the Channel key and set up 

more watering programs. 

 The program is saved and 

SELECT  CHANNEL  

SELECT  CHANNEL  

and 

the channel flash (program step 1.).

10.  [ Fig.  O17 ]:  Press the Channel key. 

The programs have been set up and the main 

level is displayed.

The main level displays the next programmed 

watering. In this example: watering on 2  

(Channel   ), watering start time 16:30  

(Start Time 

16:30

16:30

) on Monday ( Mo ).

Programming of the Watering Controller is now 

completed, i. e. the valves installed open / close 

entirely automatically and therefore water at the 

 programmed  times.

Changing an existing watering program:

You can change an existing program stored in 

one of the 3 program memory locations without 

having to create the program from scratch.

The data for the watering start time, duration, and 

cycle are preset; therefore you only need to change 

the specific values of the watering program you 

want to change. You can transfer all other values 

from Setting the watering programs by pressing  

the OK key.

4.2. Special Functions

Blocking a channel:

If Program Off is selected as program memory 

location for a channel, the respective channel is 

blocked and the watering programs of the chan-

nel are no longer executed. The programs of the 

channel are retained.

You can end the programming mode at any time by 

pressing the Channel key.
1. [ Fig.  O7 ]:  Press the Channel key. 

SELECT  CHANNEL

SELECT  CHANNEL

 and the channel flash.

2. [ Fig.  O8 ]:  Select the channel using the  

-

 keys (e. g. channel 2) and confirm by 

 pressing  the  OK key. 

 Channel appears on the display (e. g. 2) and 

Select Program and the program memory 

location flash.

3. [ Fig.  O18 ]:  Select the program memory 

 location  Off using the 

-

 keys and confirm  

by pressing the OK key. 

SELECT  CHANNEL

SELECT  CHANNEL

 flashes in the display.

4. [ Fig.  O19 ]:  Press the Channel key. 

 

CHANNEL  OFF

CHANNEL  OFF

 and the channel (e. g. channel 2) is 

shown in the display.

If several channels are blocked, 

CHANNELS  OFF  

CHANNELS  OFF  

is 

 displayed. If the Run Time % is not equal to 100,  

the display alternates every 3 seconds between 

CHANNEL  OFF

CHANNEL  OFF

 and 

RUN  TIME  %

RUN  TIME  %

.

Manual Watering (Man Key)

Manual watering:

The manual watering duration can be set between 

0 to 59 min. Channels which are already open are 

displayed in frames.

1. [ Fig.  O7 ]:  Press the Man. key. 

SELECT  CHANNEL

SELECT  CHANNEL

 and the channel flash.

2. [ Fig.  O20 ]:  Select the channel desired using  

the 

-

 keys (e. g. channel 4) and confirm by 

pressing the OK key.  

Run Time Man. and minutes flash in the  display.

3. [ Fig.  O21 ]:  Select the manual watering duration 

(

00:30

00:30

 minutes are preset) using the 

-

 keys 

(e. g. 

00:15

00:15

) and confirm by pressing the OK key. 

Manual watering starts and the frame around the 

active channel flashes.

If the watering duration is not confirmed within 

10 seconds by pressing the OK key, the watering 

begins with the watering duration selected.

17

EN

Содержание 4030

Страница 1: ...4030 Art 1283 6030 Art 1284 EN Operator s manual Watering Controller EN...

Страница 2: ...1 I2 MASTER VALVE MASTER SENSOR CHANNELS 5 3 4 M F1 I3 MASTER VALVE MASTER SENSOR CHANNELS F2 W Z Q U R E T I1 1 2 I4 6 7 6 6 O1 O2 O3 O4 O5 O6 O7 O8 2...

Страница 3: ...O9 O10 O11 O12 O13 O14 O15 O16 O17 O18 O19 O20 O21 O22 O23 O24 O25 O26 O27 O28 O29 O30 3...

Страница 4: ...ions provid ed by GARDENA is a prerequisite for proper use of the Watering Controller Please note The Watering Controller must be used only for controlling commercially available 24 V AC valves The el...

Страница 5: ...f the particular channel is being programmed If a channel is currently open the frame of the opened watering channel flashes T Display of watering times Indicates the start time and duration of wateri...

Страница 6: ...cable of the valve V2 to a cable terminal C of the valve box Other valves can be connected similarly to V1 and V2 Connecting the Watering Controller to the Valve Box Connect a cable terminal C of the...

Страница 7: ...rams Ending the programming mode prematurely You can exit the programming mode prematurely at any time v Press the Channel key twice The main level is displayed Setting the watering programs PLEASE NO...

Страница 8: ...u only need to change the specific values of the watering program you want to change You can transfer all other values from Setting the watering programs by pressing the OK key 4 2 Special Functions B...

Страница 9: ...grams 1 Fig O24 Press the Run Time key RUN TIME RUN TIME and the percentage watering duration flash 2 Fig O25 Select the figure for the percentage watering duration using the keys e g RUN RUN TIME 60...

Страница 10: ...pply unit into a mains socket OVERLOAD OVERLOAD is indicated on the display the programs are retained The power supply is overloaded because valves from other manufacturers have been used v Only so ma...

Страница 11: ...al or manufac turing faults This war ranty is fulfilled by supplying a fully functional replacement product or by repair ing the faulty product sent to us free of charge we reserve the right to choose...

Страница 12: ...nnel Prog START TIME START TIME RUN TIME RUN TIME 24h 2nd 3rd Odd Even Mo Tu We Th Fr Sa Su 1 2 3 Channel Prog START TIME START TIME RUN TIME RUN TIME 24h 2nd 3rd Odd Even Mo Tu We Th Fr Sa Su 1 2 3 C...

Страница 13: ...os korjauksia ei ole tehnyt GARDENAn hyv ksy m huolto liike tai jos niiden syyn on muiden kuin alkuper isten GARDENA varaosien tai GARDENAn hyv ksymien varaosien k ytt IT Responsabilit del prodotto In...

Страница 14: ...S 103 92 Tukholma Ruotsi valtuuttamana henkil n ett seuraava laite t ytt seuraavat laitteet t ytt v t meid n toimittamassa mallissa yhdenmukaistet tujen EU direktiivien EU turvallisuusm r ysten ja tuo...

Страница 15: ...E Kennzeichnung Year of CE marking Ann e d apposition du marquage CE Installatiejaar van de CE aanduiding CE M rknings r CE M rknings r CE merkin kiinnitysvuosi Anno di applicazione della certificazio...

Страница 16: ...County Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia Spa Centro Direzionale Planum Via del Lavoro 2 Scala B 22036 ERBA CO Tel 39 031 4147700 assistenza italia it husqvarna com Ja...

Отзывы: