Electronic control display
Power ON display:
The pump is connected to the mains.
Pump ON display:
The pump is pumping.
Manual display:
Only displayed in manual operation.
l/h or bar display:
Indicates whether throughput or pressure is being displayed.
Frost symbol:
The temperature in the pump was or is below 3 °C.
MMIINN MMAAXX
display:
MIN:
The throughput is below 300 l/h (5 l/min)
MAX:
The throughput is at maximum.
Reset key:
Used for resetting the throughput indicator
, cancelling
the frost symbol and restarting after a fault.
Shift key:
Used for moving the display forwards.
Manual key:
Used for pumping manually if the shift key is pressed at the
same time.
Operating modes
Priming cycle
Throughput during operation
(pump is delivering water)
Standby
16
GB
Pump tries to draw in water
for a maximum of 4 minutes.
Throughput > 300 l/h to
MAX
(display in 100 l/h increments).
Maximum throughput.
Throughput > 140 l/h and
less than 300 l/h.
Throughput < 140 l/h.
No water is being drawn off
and the pump has switched
off at maximum pressure.
Pump ON
flashes.
Pump ON
flashes.