background image

2

If you choose to vary from these instructions your 

warranty will be impaired.

If you need advice, call us 

FREE

 on 

0800 807 433

 

or email us at [email protected]

!

i

COMPONENTS CHECKLIST

Please check the parts carefully and advise immediately if any are damaged or missing.

A

3 x 1830mm sheets for back

B

6 x 1200mm sheets for roof

C

4 x sloping sheets & 

2 x gable cut sheets for ends

D

1 x 780mm wide sheet with  

door jamb attached

E

Door pre-hinged to 700mm 

sheet with door jamb

F

4 x 2255mm channels with 

ends cut for front and  

back walls

G

4 x 2255mm channels  

for roof

H

2 x 2255mm channels for 

bottom & 2 x 2290mm 

channels for top of end walls

I

4 x 1200mm ‘L’s for flashing 

the roof to the end walls

L

2 x gable plates for  

gable ends

N

2 x ‘Z’ door braces

Pan

Rib

2 x 793mm door spacers

J

1 x pack of rivets with padbolt for Zincalume sheds, rivets for colour 

sheds, 2 x ‘Z’ door braces and riveter for general assembly

M

1 x 2255 mm ridge beam

K

IMPORTANT!

• 

Remove the swarf (drill filings) from the panels as you assemble them.

• 

All components are cut to length. Do not cut any parts unless instructed.

• 

Rivets through the inside of the channels into the sheeting are just as important 

as rivets from the outside.

RIBS AND PANS

• 

Generally most rivets are spaced at 300mm apart.

• 

Keep the rivets in the pans as close to the ribs as possible for added strength.

• 

Ribs will always protrude to the outside of the shed.

• 

Extra internal rivets are strongly recommended in high wind areas.

DIAGRAM 1

DIAGRAM 2

DIAGRAM 3

BUILDING YOUR SHED

The basic task is to join the sheets together to form your 

panels, and rivet channels to the top and bottom of these 

panels. They will then join together to form your shed 

(diagram 1, 2 and 3).

Содержание GM2323

Страница 1: ...embling DO NOT attempt to erect this shed in windy weather All dimensions are approximate BEFORE YOU BEGIN To avoid any confusion with your new shed build we strongly suggest that you unpack and identify each part before you begin to put it together ASSEMBLY INSTRUCTIONS YOU SHOULD HAVE TWO PACKAGES 1 cardboard package 1 channel pack TOOLS SUPPLIED 1 riveter 3 3mm double ended drillbit TOOLS REQUI...

Страница 2: ...r braces Pan Rib 2 x 793mm door spacers J 1 x pack of rivets with padbolt for Zincalume sheds rivets for colour sheds 2 x Z door braces and riveter for general assembly M 1 x 2255 mm ridge beam K IMPORTANT Remove the swarf drill filings from the panels as you assemble them All components are cut to length Do not cut any parts unless instructed Rivets through the inside of the channels into the she...

Страница 3: ...hannel 1 x 2255mm bottom channel 2 x 793mm door spacers D E F J The higher side of the channel goes to the inside of the shed It is very important to include the rivets on the underside of all the channels as they are structural except roof channels FITTING CHANNELS OUTSIDE INSIDE The cutouts go to the inside of the panel to allow easy fitment of the end walls on assembly CHANNELS WITH CUTOUTS BOT...

Страница 4: ...an of the sheet YOU WILL NEED 6 x 1200mm long sheets 4 x 2255mm channels 4 x 1200mm L s 1 x 2255mm ridge beam B G I K STEP 3 ROOF 1 Join 3 B 1200mm sheets together same as the back 2 Cap sheeting with G 2255mm channels 3 Rivet the channels at every second rib but not the corners at this stage 4 Place the short flange of I L on top of the rib at 1 end Make sure ends are flush with sheeting and put ...

Страница 5: ...able ends C H L YOU WILL NEED 2 x Z Door braces Rivets for Zincalume sheds Rivets for Colour sheds N M M STEP 5 DOOR BRACES 1 The door braces can be riveted now or after you have assembled your shed 2 Tuck one end of the Z between the bottom channel of the inside of the door and the sheet Do the same at the top overlapping in the centre behind the padbolt If you have a locking T handle you will ha...

Страница 6: ...sert second roof panel into the ridge and rivet off both sides If it is difficult to get the same overhang at each end this will be caused by an unlevel site or walls that are not square Adjust accordingly Fix the L s at 300mm apart Using the ladder and the tape measure rivet down through the top of the roof through the pan into the top channel of the front and the back walls 10mm more than the ov...

Страница 7: ...vailable from your shed dealer BOXING DIAGRAM 20MM 25MM 1 X 1 INTERNAL DIMENSIONS APPROX 25MM RECESS AROUND THE OUTSIDE 25MM 2235MM INTERNAL MEASUREMENT 2235MM PEG THE FLOOR TO THE GROUND IN WINDY AREAS RUNNER SHED FLOOR BOARD SHED RECESS 20MM 25MM 8MM BOLT SET INTO CONCRETE 100MM 25MM 25MM APPROX 20MM 25MM 2235MM X 2235MM INTERNAL DIMENSIONS FOR THE GM2323 STEP 7 COMPLETE YOUR SHED RECESSED CONCR...

Страница 8: ...ted timber sits directly on the ground The floor may need pegging into the ground in windy areas 4 HOOKS Coming in a set of four WE WOULD REALLY LIKE YOUR FEEDBACK Please email your comments to feedback gardenmastersheds co nz or fax us on 06 878 5758 Customer satisfaction is our top priority and we are always on the look out for ways in which we could do better FREE GIFT To receive your free gift...

Отзывы: